Time setting for Filters during Analog Operation :
The Analog Input Filter increases response time, and enables the linear operation of the motor in
the event of a fluctuating analog input signal being received.
In SSM-6 Motors, the filter time can be set, when required, to suit the analog input. The response
time can be set from 0 to 5 seconds to avoid sudden changes in signal fluctuations or
interferences.
Figure 29 :
Time setting menu for analog filter