23
d - ) Programmable two dry contact outputs :
In Merkür motors, two existing contacts can give warning outputs in specified angles. See
Figure
15
for programming.
Figure 15 :
Program menu of contacts
The contact current of the digital output relays
is
24 VDC 1 Amp.
The electrical connection
should be made as shown in
Figure 16
if the
contact output function is to be used. Do apply
loads up above the specified current so as not to
damage the main board of the SSM-6. Strengthen
the outputs with a second relay.
Figure 16:
Contact
electrical connection
9 : Central contact L ( + )
10
: DO 1. Relay contact output (NA)
11
: DO 2. Relay contact output (NA)
N
: Neutral
WARNING
Contact Output Connection