Page 400 of 544
NT5K21 XMFC/MFE card
553-3011-100
Standard 14.00
January 2002
Signaling levels
MFC signaling uses pairs of frequencies to represent digits, and is divided
into two levels:
Level 1:
used when a call is first established and may be used to send the
dialed digits.
Level 2:
used after Level 1 signaling is completed and may contain such
information as the status, capabilities, or classifications of both calling
parties.
Forward and backward signals
When one NT5K21 XMFC/MFE card sends a pair of frequencies to a
receiving XMFC/MFE card (forward signaling), the receiving XMFC/MFE
card must respond by sending a different set of frequencies back to the
originating XMFC/MFE card (backward signaling). In other words, the
receiving card is always “compelled” to respond to the originating card.
In summary, the signaling works as follows:
•
The first XMFC/MFE card sends a forward signal to the second card.
•
The second card hears the forward signal and replies with a backward
signal.
•
The first card hears the backward signal and “turns off” its forward
signal.
•
The second card hears the forward signal being removed and removes its
backward signal.
•
The first XMFC/MFE can either send a second signal or drop out of the
call.
Summary of Contents for Meridian 1 Option 11C Mini
Page 2: ......
Page 8: ...Page 8 of 544 Contents 553 3011 100 Standard 14 00 January 2002 ...
Page 10: ...Page 10 of 544 About this guide 553 3011 100 Standard 14 00 January 2002 ...
Page 86: ...Page 86 of 544 Memory Storage and CPU capacity 553 3011 100 Standard 14 00 January 2002 ...
Page 176: ...Page 176 of 544 Transmission parameters 553 3011 100 Standard 14 00 January 2002 ...
Page 196: ...Page 196 of 544 Spares planning 553 3011 100 Standard 14 00 January 2002 ...
Page 226: ...Page 226 of 544 System Controller cards 553 3011 100 Standard 14 00 January 2002 ...
Page 260: ...Page 260 of 544 The TDS DTR card 553 3011 100 Standard 14 00 January 2002 ...
Page 282: ...Page 282 of 544 M2317 Telephone 553 3011 100 Standard 14 00 January 2002 ...
Page 308: ...Page 308 of 544 Meridian Modular Telephones 553 3011 100 Standard 14 00 January 2002 ...
Page 364: ...Page 364 of 544 M2250 Attendant Console 553 3011 100 Standard 14 00 January 2002 ...
Page 388: ...Page 388 of 544 NT8D14 Universal Trunk Card 553 3011 100 Standard 14 00 January 2002 ...
Page 408: ...Page 408 of 544 NT5K21 XMFC MFE card 553 3011 100 Standard 14 00 January 2002 ...
Page 414: ...Page 414 of 544 NTAG26 XMFR card 553 3011 100 Standard 14 00 January 2002 ...
Page 422: ...Page 422 of 544 NT6D71 UILC line card 553 3011 100 Standard 14 00 January 2002 ...
Page 492: ...Page 492 of 544 NTAK79 2 0 Mb PRI card 553 3011 100 Standard 14 00 January 2002 ...
Page 512: ...Page 512 of 544 NTAK20 clock controller 553 3011 100 Standard 14 00 January 2002 ...
Page 518: ...Page 518 of 544 NTAK93 D channel handler interface 553 3011 100 Standard 14 00 January 2002 ...
Page 544: ...Page 544 of 544 Index 553 3011 100 Standard 14 00 January 2002 ...