NTAK79 2.0 Mb PRI card
Page 485 of 544
Option 11C and 11C Mini
Technical Reference Guide
Carrier grounding
NTAK79 provides for the capability of selectively grounding the shield of the
Tx and/or Rx pairs of the carrier. Closing (down) the on-board switch will
apply FGND to the appropriate carrier cable shield. The switch settings are
shown below.
Receiver functions
The receiver extracts data and clock from an AMI (Alternate Mark Inversion)
coded signal and outputs clock and synchronized data. The receiver is
sensitive to signals over the entire range of cable lengths and requires no
equalization. The clock and data recovery meets or exceeds the jitter
specifications of the CCITT recommendation G.823 and the jitter attenuation
requirements of CCITT recommendation G.742. This provides jitter
attenuation increasing from 0 dB to 60 dB over the frequency range from
about 6 Hz to 6 KHz.
Transmitter functions
The transmitter takes the binary (dual unipolar) data from the PCM
transceiver and produces bipolar pulses which conform to CCITT
recommendation G.703 pulse shape.
Loopbacks
The remote loopback function causes the device to transmit the same data that
it receives using the jitter attenuated receive clock. The data is additionally
available at the receive data outputs. Local loopback causes the transmit data
and clock to appear at the receive clock and data outputs. This data is also
transmitted on the line unless transmit AIS is selected.
Table 151
Carrier shield grounding switch settings
Switch
Carrier Pair
On
Off
S4-1
Rx shield
Open
GND
S4-2
Tx shield
Open
GND
Summary of Contents for Meridian 1 Option 11C Mini
Page 2: ......
Page 8: ...Page 8 of 544 Contents 553 3011 100 Standard 14 00 January 2002 ...
Page 10: ...Page 10 of 544 About this guide 553 3011 100 Standard 14 00 January 2002 ...
Page 86: ...Page 86 of 544 Memory Storage and CPU capacity 553 3011 100 Standard 14 00 January 2002 ...
Page 176: ...Page 176 of 544 Transmission parameters 553 3011 100 Standard 14 00 January 2002 ...
Page 196: ...Page 196 of 544 Spares planning 553 3011 100 Standard 14 00 January 2002 ...
Page 226: ...Page 226 of 544 System Controller cards 553 3011 100 Standard 14 00 January 2002 ...
Page 260: ...Page 260 of 544 The TDS DTR card 553 3011 100 Standard 14 00 January 2002 ...
Page 282: ...Page 282 of 544 M2317 Telephone 553 3011 100 Standard 14 00 January 2002 ...
Page 308: ...Page 308 of 544 Meridian Modular Telephones 553 3011 100 Standard 14 00 January 2002 ...
Page 364: ...Page 364 of 544 M2250 Attendant Console 553 3011 100 Standard 14 00 January 2002 ...
Page 388: ...Page 388 of 544 NT8D14 Universal Trunk Card 553 3011 100 Standard 14 00 January 2002 ...
Page 408: ...Page 408 of 544 NT5K21 XMFC MFE card 553 3011 100 Standard 14 00 January 2002 ...
Page 414: ...Page 414 of 544 NTAG26 XMFR card 553 3011 100 Standard 14 00 January 2002 ...
Page 422: ...Page 422 of 544 NT6D71 UILC line card 553 3011 100 Standard 14 00 January 2002 ...
Page 492: ...Page 492 of 544 NTAK79 2 0 Mb PRI card 553 3011 100 Standard 14 00 January 2002 ...
Page 512: ...Page 512 of 544 NTAK20 clock controller 553 3011 100 Standard 14 00 January 2002 ...
Page 518: ...Page 518 of 544 NTAK93 D channel handler interface 553 3011 100 Standard 14 00 January 2002 ...
Page 544: ...Page 544 of 544 Index 553 3011 100 Standard 14 00 January 2002 ...
Page 545: ......