— self-test status
— programmed configuration status
•
receipt and implementation of card configuration:
— of the codecs
— enabling/disabling of individual units or entire card
— programming of input/output interface control circuits for
administration of line interface unit operation
— maintenance diagnostics
— transmission loss levels
Signaling and control
—This portion of the card provides circuits that
establish, supervise, and take down call connections. These circuits work
with the system CPU to operate line interface circuits during calls. The
circuits receive outgoing call signaling messages from the CPU and return
incoming call status information over the DS-30X network loop.
Circuit Power
The +8.5 V dc input is regulated down to + 5 V dc for use by the digital logic
circuits. All other power to the card is used by the line interface circuits.
Foreign and surge voltage protection
The OPS analog line card meets UL-1489 and CS03 over-voltage (power
cross) specifications and FCC Part 68 requirements for hazardous and surge
voltage limits.
Software service changes
Individual line interface units on the OPS analog line card are configured to
either OPS (for OPS application) or ONS (for ONS application) class-of-
service (CLS) in the Single-line Telephone Administration program (LD10)
(see Table 133). LD10 is also used to select unit terminating impedance and
balance network impedance at the TIMP and BIMP prompts, respectively.
See the
Maintenance
(553-3001-511) for LD 10 service change instructions.
Summary of Contents for Meridian 1 Option 11C Mini
Page 2: ......
Page 8: ...Page 8 of 544 Contents 553 3011 100 Standard 14 00 January 2002 ...
Page 10: ...Page 10 of 544 About this guide 553 3011 100 Standard 14 00 January 2002 ...
Page 86: ...Page 86 of 544 Memory Storage and CPU capacity 553 3011 100 Standard 14 00 January 2002 ...
Page 176: ...Page 176 of 544 Transmission parameters 553 3011 100 Standard 14 00 January 2002 ...
Page 196: ...Page 196 of 544 Spares planning 553 3011 100 Standard 14 00 January 2002 ...
Page 226: ...Page 226 of 544 System Controller cards 553 3011 100 Standard 14 00 January 2002 ...
Page 260: ...Page 260 of 544 The TDS DTR card 553 3011 100 Standard 14 00 January 2002 ...
Page 282: ...Page 282 of 544 M2317 Telephone 553 3011 100 Standard 14 00 January 2002 ...
Page 308: ...Page 308 of 544 Meridian Modular Telephones 553 3011 100 Standard 14 00 January 2002 ...
Page 364: ...Page 364 of 544 M2250 Attendant Console 553 3011 100 Standard 14 00 January 2002 ...
Page 388: ...Page 388 of 544 NT8D14 Universal Trunk Card 553 3011 100 Standard 14 00 January 2002 ...
Page 408: ...Page 408 of 544 NT5K21 XMFC MFE card 553 3011 100 Standard 14 00 January 2002 ...
Page 414: ...Page 414 of 544 NTAG26 XMFR card 553 3011 100 Standard 14 00 January 2002 ...
Page 422: ...Page 422 of 544 NT6D71 UILC line card 553 3011 100 Standard 14 00 January 2002 ...
Page 492: ...Page 492 of 544 NTAK79 2 0 Mb PRI card 553 3011 100 Standard 14 00 January 2002 ...
Page 512: ...Page 512 of 544 NTAK20 clock controller 553 3011 100 Standard 14 00 January 2002 ...
Page 518: ...Page 518 of 544 NTAK93 D channel handler interface 553 3011 100 Standard 14 00 January 2002 ...
Page 544: ...Page 544 of 544 Index 553 3011 100 Standard 14 00 January 2002 ...
Page 545: ......