Specifications
Case
Description
Durable case, hinged lid, four press & pull latches, weather resistant
when closed.
Dimensions
External dimensions: Length × Width × Depth.
25 in × 20 in × 12 in (63.5 cm × 50.8 cm × 30.48 cm).
Weight
The case weight with the PIT5000 equipment is
42 lbs
.
Mobility
In-line wheels.
An extendable handle.
Three additional handles around the perimeter.
External Power
115 V ac to 12 V dc power supply (charger assembly) has a cord that
is 9.5 feet.
12 V dc has a cord that is 25 feet (12 V locking, ring terminals).
Pressure limits
PIT5000 sensor: 0 psi to 3300 psi
Do not exceed the sensor limit.
Full Scale calibrated range = 100 % of range.
The PIT5000 application does not alert you to pressure limits.
Stroke Counter
PIT5000 su5 V output to pump for Stroke Counter function.
M12 connection to PIT5000 through the Meriam cable with number 8
spade terminals for connection to dry contacts.
Maximum count rate: 300 strokes per minute.
Connections
Pressure
Quick-test fitting and hose.
Temperature
One M12 (female) for ambient temperature.
One M12 (female) for pipe temperature.
Stroke Counter
M12 (female).
Power
12 V car adapter.
12 V locking connector.
Operating temperature range
Computer working
temperature
5 ºC to 35 ºC (41 ºF to 95 ºF)
Storage temperature
–
20 ºC to 60 ºC (
–
4 ºF to 140 ºF)
Summary of Contents for PIT5000
Page 1: ...The PIT5000 Pipeline Integrity Tester A Pipeline Hydrostatic Testing Device...
Page 2: ...Introductory information Notification Statements Disclaimer Copyright...
Page 6: ...Protect the PIT5000 Protect the PIT5000 Do not substitute parts...
Page 12: ...Hardware Recommended power connections...
Page 13: ...Temporary power connections...
Page 19: ...3 Computer pane Computer pane 4 Measure pane Measure pane 1 2 3 4...
Page 33: ...PC Setup sub tab continued Build Report button...