CMT01 User Manual 

3)

 

The meter is powered by a single 9V PP3 battery. Snap the 

battery connector leads to the terminals of a new battery and 
reinsert the battery into the case top. Dress the battery leads so 
that they will not be pinched between the case bottom and case 

top. 

Replace the case bottom and reinstall the screw. Never operate the 

meter unless the case bottom is fully closed. 

 

ACCESSORIES 

 

Instruction manual 

 

Set of test leads (red and black) 

 

9V PP3 battery 

 

    

EN61010–1:2010

 

 

 

 

 

This product is classed as Electrical or Electronic equipment  

and should not be disposed with other household or commercial  

waste at the end of its useful life. The goods must be disposed  

of according to your local council guidelines. 

 
 

 

Errors and omissions excepted. 

 

Copyright©  2014. AVSL Group Ltd.

 

Summary of Contents for CMT01

Page 1: ...Item ref 600 103UK CMT01 DIGITAL CLAMP MULTITESTER User Manual ...

Page 2: ... as marked on the tester between the terminals or between any terminal and grounding The rotary switch should be in the right position and no changeover of range shall be made during measurement is conducted to prevent damage When the tester is working at an effective voltage over 60V in DC or 30Vrms in AC special care should be taken for there is danger of electric shock Use the proper terminals ...

Page 3: ... should be used to prevent the surface of the tester from corrosion or damage The tester is suitable for indoor use only Turn the tester power off when it is not in use and take out the battery when not using for a long time Check the battery regularly replace the battery immediately if any signs of leaking appear Battery acid will damage the tester General Specifications Max display LCD 1999 coun...

Page 4: ...CMT01 User Manual Multitester compatible table Transformer jaw Trigger LCD COM jack V jack Data hold button Ω jack Hand Strap ...

Page 5: ... 1mV 20V 10mV 0 8 of rdg 5D 200V 100mV 600V 1V 1 0 of rdg 5D OVERLOAD PROTECTION 600Vrms AC Voltage RANGE RESOLUTION ACCURACY 200V 100mV 1 0 of rdg 5D 600V 1V 1 2 of rdg 5D Frequency Range 45Hz 450Hz Overload Protection 250Vrms AC Response Average calibrated in rms of sine wave Audible Continuity RANGE DESCRIPTION Built in buzzer sounds if resistance is less than 30 20Ω Overload Protection 250V DC...

Page 6: ...out 3V Overload Protection 250Vrms DC AC for 15 sec max OPERATING INSTRUCTIONS VOLTAGE MEASUREMENT 1 Connect red test lead to V jack black lead to COM jack 2 Set RANGE switch to desired VOLTAGE position if the voltage to be measured is not known beforehand set switch to the highest range and reduce it until satisfactory reading is obtained 3 Connect test leads to device or circuit being measured 4...

Page 7: ...range switch to desired Ω range 3 If the resistance being measured is connected to a circuit turn off power and discharge all capacitors before measurement 4 Connect test leads to circuit being measured 5 Read resistance value on Digital Display CONTINUITY TEST 1 Connect the BLACK test lead to the COM jack and the RED to the VΩ jack Note The polarity of the red test lead is positive 2 Set the rang...

Page 8: ... case bottom and reinstall the screw Never operate the meter unless the case bottom is fully closed ACCESSORIES Instruction manual Set of test leads red and black 9V PP3 battery EN61010 1 2010 This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life The goods must be disposed of according to your...

Reviews: