background image

 

CMT01 User Manual 

CURRENT MEASUREMENT 

1.

 

Ensure that “Data Hold” button is not in pressed position. 

2.

 

Set range switch to the ACA 1000A range. If the display 
indicates one or more leading zeros. Shift to the 200A range  

to improve the resolution of the measurement. 

3.

 

Press the trigger to open the transformer jaws and clamp  

one conductor only, measurements can’t be obtained when  
two or more cables are clamped at the same time. 

4.

 

Display reading is flow the conductor AC current. 

 

RESISTANCE MEASUREMENT 

1.

 

Connect red lead to “Ω”, black lead to “COM”. 

2.

 

Set the range switch to desired Ω range. 

3.

 

If the resistance being measured is connected to a circuit, turn 

off power and discharge all capacitors before measurement. 

4.

 

Connect test leads to circuit being measured. 

5.

 

Read resistance value on Digital Display. 

 

CONTINUITY TEST 

1.

 

Connect the BLACK test lead to the “COM” jack and the RED 

to the “VΩ” jack (Note: The polarity of the red test lead is 
positive “+”). 

2.

 

Set the range switch to   range 

3.

 

Connect the test leads across the load to be measured. 

4.

 

If the circuit resistance is lower than about 30±20Ω,  

the built-in buzzer will sound. 

 

BATTERY REPLACEMENT 

1)

 

Battery and fuse replacement should only be done after the test 

leads have been disconnected and power is off. 

2)

 

Loosen screw with suitable screwdriver and remove case. 

Summary of Contents for CMT01

Page 1: ...Item ref 600 103UK CMT01 DIGITAL CLAMP MULTITESTER User Manual ...

Page 2: ... as marked on the tester between the terminals or between any terminal and grounding The rotary switch should be in the right position and no changeover of range shall be made during measurement is conducted to prevent damage When the tester is working at an effective voltage over 60V in DC or 30Vrms in AC special care should be taken for there is danger of electric shock Use the proper terminals ...

Page 3: ... should be used to prevent the surface of the tester from corrosion or damage The tester is suitable for indoor use only Turn the tester power off when it is not in use and take out the battery when not using for a long time Check the battery regularly replace the battery immediately if any signs of leaking appear Battery acid will damage the tester General Specifications Max display LCD 1999 coun...

Page 4: ...CMT01 User Manual Multitester compatible table Transformer jaw Trigger LCD COM jack V jack Data hold button Ω jack Hand Strap ...

Page 5: ... 1mV 20V 10mV 0 8 of rdg 5D 200V 100mV 600V 1V 1 0 of rdg 5D OVERLOAD PROTECTION 600Vrms AC Voltage RANGE RESOLUTION ACCURACY 200V 100mV 1 0 of rdg 5D 600V 1V 1 2 of rdg 5D Frequency Range 45Hz 450Hz Overload Protection 250Vrms AC Response Average calibrated in rms of sine wave Audible Continuity RANGE DESCRIPTION Built in buzzer sounds if resistance is less than 30 20Ω Overload Protection 250V DC...

Page 6: ...out 3V Overload Protection 250Vrms DC AC for 15 sec max OPERATING INSTRUCTIONS VOLTAGE MEASUREMENT 1 Connect red test lead to V jack black lead to COM jack 2 Set RANGE switch to desired VOLTAGE position if the voltage to be measured is not known beforehand set switch to the highest range and reduce it until satisfactory reading is obtained 3 Connect test leads to device or circuit being measured 4...

Page 7: ...range switch to desired Ω range 3 If the resistance being measured is connected to a circuit turn off power and discharge all capacitors before measurement 4 Connect test leads to circuit being measured 5 Read resistance value on Digital Display CONTINUITY TEST 1 Connect the BLACK test lead to the COM jack and the RED to the VΩ jack Note The polarity of the red test lead is positive 2 Set the rang...

Page 8: ... case bottom and reinstall the screw Never operate the meter unless the case bottom is fully closed ACCESSORIES Instruction manual Set of test leads red and black 9V PP3 battery EN61010 1 2010 This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life The goods must be disposed of according to your...