background image

                                                          FMUSER INTERNATIONAL GROUP INC. 

广州市汉婷生物技术开发有限公司

 

 

 

 

 

 

 

 

 

 

FUTV4207A Multiplexer 

 

User’s Manual 

 

 

 

 

 

 

SNMP Version: 2.2.5   

Software: 1.23 

Hardware: 1.7 

 

 

 
 
 

 

FMUSER International Group Inc

Summary of Contents for FUTV4207A

Page 1: ...FMUSER INTERNATIONAL GROUP INC FUTV4207A Multiplexer User s Manual SNMP Version 2 2 5 Software 1 23 Hardware 1 7 FMUSER International Group Inc...

Page 2: ...TALLATION GUIDE 7 2 1 ACQUISITION CHECK 7 2 2 INSTALLATION PREPARATION 7 2 3 WIRE S CONNECTION 9 2 4 SIGNAL CABLE CONNECTION 10 CHAPTER 3 OPERATION 12 3 1 MAIN INTERFACE 12 3 2 GENERAL SETTING 13 CHAP...

Page 3: ...it IP output with two separate channel The bit rate of output stream can be up to 216Mbps 1 2 Features l Fully complying with ISO13818 and EN300 468 standard l Integrated demodulating and multiplexing...

Page 4: ...tomatic generating PSI SI table Input Packet format 204 188 self adaption Output port ASI 2 groups of separate outputs each group has 2 channels IP 2 channels of separate IP outputs share one GE Ether...

Page 5: ...rinciple Chart ASI TS 1 ASI TS 2 ASI TS 3 ASI TS 8 MUX 1 ASI TS 6 ASI TS 7 MUX 2 ASI output ASI output IP output IP output 1 5 Appearance and Description Front panel Illustration Indicator area All th...

Page 6: ...ASI 2 same as ASI 1 ASI 3 same as ASI 1 ASI 4 same as ASI 1 ASI 5 same as ASI 1 ASI 6 same as ASI 1 ASI 7 same as ASI 1 ASI 8 same as ASI 1 3 UP DOWN LEFT RIGHT Key 4 Enter Confirmation key 5 MENU Ke...

Page 7: ...TS input of port 7 ASI IN8 TS input of port 8 8 ASI OUT A1 TS output of port A1 A2 TS output of port A2 B1 TS output of port B1 B2 TS output of port B2 9 NMS Ethernet Port 10 100Mbps 10 Data port two...

Page 8: ...device please follow the below steps The details of installation will be described at the rest part of this chapter Users can also refer rear panel chart during the installation The main content of t...

Page 9: ...ing resistance 1M Floor bearing should be greater than 450Kg Environment Temperature 5 40 sustainable 0 45 short time installing air conditioning is recommended Relative Humidity 20 80 sustainable 10...

Page 10: ...re the 2 ends of grounding wire well electric conducted and be antirust l It is prohibited to use any other device as part of grounding electric circuit l The area of the conduction between grounding...

Page 11: ...be smaller than 1 FCaution Before connecting power cord to FUTV4207A multiplexer user should set the power switch to OFF 2 4 Signal Cable Connection The signal connections include the connection of i...

Page 12: ...ed in the rear panel illustration and then connect the ASI cable in the accessories one end is connected to the Multiplexer s ASI output port and the other end to the Modulator s ASI input port or ASI...

Page 13: ...er or paging up down when parameter is inactivated LOCK Locking the screen canceling the lock state After pressing lock key the system will question the users to save present setting or not If not the...

Page 14: ...nu 1 1 1 the first row displays the port number and the quantity of programs for example Port 1 means the TS stream comes from port 1 and the Prog 8 means the quantity of the programs is 8 The descrip...

Page 15: ...owing the effective bit rate of multiplexed programs from all input ports and the bit rate of stuffed null pockets 3 2 2 1 2 TransStream ID This is a 16 bit field which serves as a label for identific...

Page 16: ...and settings of 2 2 PORT 2 are the same as the 2 1 PORT 1 3 2 2 3 UTC Time Config User can set the UTC time Coordinated Universal Time at this submenu 3 2 3 Network Setting 2 1 4 Out Address 224 002 0...

Page 17: ...according to the factory setting and it s unique 3 2 3 6 NMS Port This port can be used as communication port for NMS management 3 2 4 Saving Config User can choose NO or YES to save the current confi...

Page 18: ...ed CFG and also user can restore the device into factory configuration by choosing the menu 5 2 Load Default CFG 3 2 6 Version User can check the device s hardware version and software version at this...

Page 19: ...click to run this application program 4 2 Software Operation 4 2 1 Login Interface A login interface will pop up firstly when the software is running and give user prompts to input user name and pass...

Page 20: ...te a device node tree in the left column by adding modifying and deleting the device node This software provides a powerful node operation function and the user can edit various parameters in the devi...

Page 21: ...ouse key to pop up the short cut menu in device tree or in the left blank column then the corresponding dialog box will pop up by choosing Add Main Freq Point The device will confirm the given frequen...

Page 22: ...he Equipment Name l Choosing the connected equipment type in drop down list of Equipment Type by clicking the Or Click to auto search the type of device NOTE 1 The default IP of FUTV4207A is 192 168 0...

Page 23: ...m in the drop down menu which appears by clicking the right mouse key 4 2 7 Save Configuration After finishing all the parameters setting user can click button on the toolbar to save the modifications...

Page 24: ...red binary file and set the device s parameters according to the loaded binary files 4 3 FUTV4207A Multiplexer Operation User can choose the Tuner Input Multiplexer in the device tree Set making the c...

Page 25: ...FMUSER INTERNATIONAL GROUP INC 24 41 4 3 1 Input FUTV4207A has 8 ASI inputs 4 3 2 Output Setting 4 3 2 1 Mux Multiplex...

Page 26: ...resent the output programs and the input channel they are from User can analyze the programs of each input port and multiplex those programs to the output Port 1 or Port 2 or both port 1 and Port 2 Mo...

Page 27: ...n user can select the target program in output part first and click this button to pop up a dialog box as below Select the target item and input the new value in the box below then click and to effect...

Page 28: ...this interface In some occasions there are some PIDs which won t belong to any program such as EPG NIT tables and so on but user just wants to pass them through the multiplexing module without changin...

Page 29: ...umber while it could be different if a PID remapping is needed Modify the data as needed and click OK to confirm The PID then will be bypassed and listed in the table as below Other functions User can...

Page 30: ...ormation in the PID Pass To read the PID Pass from device 4 3 2 3 NIT Insertion NIT Network Information Table NIT table is a very important table for describing the network and TS Users can set the pa...

Page 31: ...o parts One is descriptor tag and the other is descriptor information The Descriptor Tag is an 8 bit field which identifies each descriptor The Descriptor Data is the detailed information of the priva...

Page 32: ...IT parameters being added The Modify button will trigger a modify window and allow user to modify the selected items in the NIT The Delete button will remove the selected items in the NIT The set Butt...

Page 33: ...F Total Output Bit rate User can set the total output bit rate at this field The value of this bit rate includes the following the effective bit rate of multiplexed programs from all input ports and t...

Page 34: ...FMUSER INTERNATIONAL GROUP INC 33 41 4 3 3 System User can set the output IP gateway address and Service IP Mask address in this tag Click and then to make it effective 4 3 4 Real time Monitor...

Page 35: ...indicates the maximum bit rate of corresponding channel whose real time output effective bit rate ever reached 4 4 Other Settings 4 4 1 Difference between Set and Remote Save In many cases during the...

Page 36: ...new NMS IP Address for the device and click OK button to confirm Users can then note the indicator light turns red which signifies the equipment has disconnected Users then can refer to below prompts...

Page 37: ...ault user name is admin and no password User can add users and passwords as needed User clicking Setting in the menu bar and selecting User Setting in the pull down list the below dialog box will pop...

Page 38: ...FMUSER INTERNATIONAL GROUP INC 37 41...

Page 39: ...ween 0 to 45 C l Making sure good ventilation for the heat sink on the rear panel and other heat sink bores if necessary l Checking the input AC within the power supply working range and the connectio...

Page 40: ...FMUSER INTERNATIONAL GROUP INC 39 41 properly l Maintenance needed...

Page 41: ...FMUSER INTERNATIONAL GROUP INC 40 41 Chapter 6 Packing list l FUTV4207A ASI Input Multiplexer 1pcs l User Manual 1pcs l ASI Cable 8pcs l Power Cord 1pcs...

Reviews: