WIRING AND FLASH PATTERN SELECTION 

 

13 Flash patterns are integrated in the M80 GYROLED®. The operating mode setting must only be chosen 
when  the  M80  GYROLED®  is  on  and  using  a  mobile  magnet  (not  supplied).  The  operation  consists  in 
moving the magnet in front a position located between the reference index and the fixing hole on its right. 
 

 

 

 

A.  MOBILE MAGNET (NOT SUPPLIED) 
B.  M80 GYROLED®  
C.  REFERENCE INDEX 
D.  FIXING HOLE 
E.  N°2 POWER SUPPLY WIRE 
F.  GYROLED® SWITCH (NOT SUPPLIED) 
G.  PROTECTION FUSE* (NOT SUPPLIED) 
H.  N°1 GROUND WIRE 

 

AVAILABLE FLASH PATTERNS 

1.  R65 Rotating 
2.  R65 Double Flashing  
3.  Triple Flashing 
4.  Simple Flashing 
5.  ½ Rotating  
6.  ½ Double Flashing 
7.  ½ Triple Flashing 

8.  ½ Single Flashing 
9.  ICAO Flashing 
10. ICAO Rotating 
11. ½ ICAO Flashing 
12. ½ ICAO Rotating 
13. N°1 Led and n°8 Led 1Hz / 50% Flashing  

 

 
 

 

Do not stare directly at the GYROLED

®

 during operation, so as to avoid eye damage.

 

Summary of Contents for GYROLED M80

Page 1: ...ing mode 850mA in rotating mode at 13 5 volts Maximum consumption 5 Amps at peak Operating Temperature 40 C à 85 C R65 approval available only with blue M80 GYROLED and amber M80 GYROLED R65 marking Flashing Blue TB1 E2 0016309 Rotating Blue TB1 E2 0016311 Flashing Amber TA1 E2 0016312 Rotating Amber TA1 E2 0016310 EMC approval E2 10R05 16242 CISPR25 2008 R10 E Marking Regulation class 4 or 5 clas...

Page 2: ...cial lighting The beacon flash pattern choice must also meet these requirements The installer is therefore fully responsible for the product installation and flash pattern chosen The choice of the GYROLED M80 position on a roof vehicle must meet regulation requirements on light signalling installation M80 GYROLED Standard positioning LEDs are identified from 1 to 8 Upper view A VEHICLE FRONT B VEH...

Page 3: ...52 Fax 00 33 0 2 54 56 80 00 SAS au capital de 102 400 APE NAF 2790 Z SIRET 310 999 891 00040 Page 3 30656 00 The wiring loom passage from the GYROLED through to the vehicle interior must be absolutely waterproof The use of an impermeable seal is recommended Ø78 ISO MOUNTING A M80 GYROLED B PROTECTIVE SEAL C VEHICLE ROOF D FIXING SCREWS E POWER SUPPLY WIRING Torque screws to 2Nm maximum POLE MOUNT...

Page 4: ...mobile magnet not supplied The operation consists in moving the magnet in front a position located between the reference index and the fixing hole on its right A MOBILE MAGNET NOT SUPPLIED B M80 GYROLED C REFERENCE INDEX D FIXING HOLE E N 2 POWER SUPPLY WIRE F GYROLED SWITCH NOT SUPPLIED G PROTECTION FUSE NOT SUPPLIED H N 1 GROUND WIRE AVAILABLE FLASH PATTERNS 1 R65 Rotating 2 R65 Double Flashing ...

Reviews: