Section 5 - Maintenance
Page 114
90-899883169 DECEMBER 2007
5. Remove the quick‑connect fitting from the parts bag supplied with the engine.
6. Attach the quick‑connect fitting to a water hose.
18487
a
b
a -
Quick connect fitting (water hose
end)
b -
Water hose
7. Snap the quick‑connect fitting with the water hose into the flush socket on the engine.
a
b
c
18489
a -
Water hose
b -
Quick‑connect fitting (water hose
end)
c -
Flush socket
8. Open the water source of the water hose to a full flow.
9. Allow the water to flush the sterndrive for 30 seconds.
10. Place the remote control in neutral idle speed position and start engine.
NOTICE
Without sufficient cooling water, the engine, the water pump, and other components will
overheat and suffer damage. Provide a sufficient supply of water to the water inlets during
operation.
11. Operate the engine at idle speed in neutral gear. Do not exceed 1200 RPM.
12. Monitor the engine temperature while operating the engine.
13. Flush the engine for 5 to 10 minutes or until discharge water is clear.
14. Shut off the engine.
15. Allow the water to flush the sterndrive for 10 seconds.
16. Turn off the water source.
Summary of Contents for Axius SeaCore 350 MAG
Page 66: ...Section 3 On the Water Notes Page 58 90 899883169 DECEMBER 2007 ...
Page 72: ...Section 4 Specifications Notes Page 64 90 899883169 DECEMBER 2007 ...
Page 74: ...Section 5 Maintenance Page 66 90 899883169 DECEMBER 2007 ...
Page 140: ...Section 6 Storage Notes Page 132 90 899883169 DECEMBER 2007 ...
Page 146: ...Section 7 Troubleshooting Notes Page 138 90 899883169 DECEMBER 2007 ...