Section 6 - Storage
90-899883169 DECEMBER 2007
Page 125
6. Pump air into the system until both green indicators extend and water drains from both
sides of the engine. The port side will begin draining before the starboard side.
33144
a
b
c
d
a
d
c
33150
Closed Cooled Models
Seawater Cooled Models
a -
Blue drain plug location
b -
Blue air pump
c -
Air manifold
d -
Green indicators
7. Verify that water is draining from each opening. If not, use the
Three Point Manual
Drain System
instructions.
a
b
6133
a -
Port side drain location
b -
Starboard side drain location
8. Allow the system to drain for a minimum of five minutes. Pump air as necessary to keep
the green indicators extended.
9. Crank the engine over slightly with starter motor to purge any water trapped in the
seawater pump. Do not allow engine to start.
10. Remove the air pump from the air manifold and return it to the mounting bracket.
11. Mercury MerCruiser recommends leaving the drain system open while transporting the
boat or while performing other maintenance. This helps ensure that all water is drained.
Summary of Contents for Axius SeaCore 350 MAG
Page 66: ...Section 3 On the Water Notes Page 58 90 899883169 DECEMBER 2007 ...
Page 72: ...Section 4 Specifications Notes Page 64 90 899883169 DECEMBER 2007 ...
Page 74: ...Section 5 Maintenance Page 66 90 899883169 DECEMBER 2007 ...
Page 140: ...Section 6 Storage Notes Page 132 90 899883169 DECEMBER 2007 ...
Page 146: ...Section 7 Troubleshooting Notes Page 138 90 899883169 DECEMBER 2007 ...