Section 6 - Storage
Page 128
90-899883169 DECEMBER 2007
3. Visually verify that water is draining. If water does not drain, remove the blue drain plug
from the distribution housing and drain manually.
a
b
33152
a -
Blue drain plug
b -
Drain location ‑ orange or red
4. Allow the system to drain for a minimum of five minutes. We recommend leaving the
plugs out while transporting the boat or performing other maintenance to ensure that
all water is drained.
5. Close the drain system by rotating the blue handle clockwise until it stops or installing
the blue drain plug. The handle is fully seated when no red is visible. Do not overtighten
handle, as this action will create new threads.
Three‑Point Manual Drain System
BOAT IN THE WATER
NOTE: Use this procedure if your engine is not equipped with an air‑actuated single‑point
drain system or if the air‑actuated single point drain system fails.
1. Close the seacock (if equipped) or remove and plug the water inlet hose.
2. Remove the blue drain plug from the distribution housing (lower front, port side).
6138
a
a -
Blue drain plug
Summary of Contents for Axius SeaCore 350 MAG
Page 66: ...Section 3 On the Water Notes Page 58 90 899883169 DECEMBER 2007 ...
Page 72: ...Section 4 Specifications Notes Page 64 90 899883169 DECEMBER 2007 ...
Page 74: ...Section 5 Maintenance Page 66 90 899883169 DECEMBER 2007 ...
Page 140: ...Section 6 Storage Notes Page 132 90 899883169 DECEMBER 2007 ...
Page 146: ...Section 7 Troubleshooting Notes Page 138 90 899883169 DECEMBER 2007 ...