FUEL INJECTION DISASSEMBLY AND REASSSEMBLY
SERVICE MANUAL NUMBER 24
Page 5E-46
90-861327--1 OCTOBER 1999
Knock Sensor Module
REMOVAL
1. Remove Knock Sensor Module (KS) from electrical box.
00000
a
a -
Knock Sensor (KS) Module
2. Disconnect electrical connector at Knock Sensor Module.
CLEANING AND INSPECTION
1. Clean the external surfaces of the KS module with a dry cloth.
2. Inspect surfaces of KS module for evidence of damage.
INSTALLATION
1. Connect electrical connector to the Knock Sensor Module.
2. Place KS module in electrical box.
00000
a
a -
Knock Sensor (KS) Module
Fuel Pump Relay
REMOVAL
1. Remove fuel pump relay from electrical box.
00000
450 BLK
120 GR
Y
30
86
85
87
465 DK GRN/WHT
2C PNK
a
a -
Fuel Pump Relay
2. Disconnect electrical connector and remove fuel pump relay.
IMPORTANT: The fuel pump relay is an electrical component. DO NOT soak in any
liquid cleaner or solvent; damage may result.
INSTALLATION
1. Attach electrical connector to fuel pump relay.
2. Place fuel pump relay in electrical box.
Index