INSTALLATION
8
Form No. TS2M-0210
Countertop Cutout — TS2-B Recessed Top Models
Model
Minimum Width
Maximum Width
Minimum Depth
Maximum Depth
TS2-24B
24-1/2″ (622 mm)
24-3/4″ (629 mm)
20″ (508 mm)
20-1/4″ (514 mm)
TS2-30B
30-1/2″ (775 mm)
30-3/4″ (781 mm)
20″ (508 mm)
20-1/4″ (514 mm)
TS2-36B
36-1/2″ (927 mm)
36-3/4″ (934 mm)
20″ (508 mm)
20-1/4″ (514 mm)
TS2-42B
42-1/2″ (1080 mm)
42-3/4″ (1086 mm)
20″ (508 mm)
20-1/4″ (514 mm)
TS2-48B
48-1/2″ (1232 mm)
48-3/4″ (1238 mm)
20″ (508 mm)
20-1/4″ (514 mm)
TS2-54B
54-1/2″ (1384 mm)
54-3/4″ (1391 mm)
20″ (508 mm)
20-1/4″ (514 mm)
TS2-60B
60-1/2″ (1537 mm)
60-3/4″ (1543 mm)
20″ (508 mm)
20-1/4″ (514 mm)
TS2-66B
66-1/2″ (1689 mm)
66-3/4″ (1695 mm)
20″ (508 mm)
20-1/4″ (514 mm)
TS2-72B
72-1/2″ (1842 mm)
72-3/4″ (1848 mm)
20″ (508 mm)
20-1/4″ (514 mm)
Bracket Screw
Metallic
Countertop
Mounting Screw
Z-Bracket
Apply a bead of NSF-approved sealant between the
countertop and the mounting flange on the unit. Sealant
must be rated for use at a minimum temperature of 250° F (121° C).
Figure 10. TS2-B Recessed Top Model Installation
8. Remove any excess sealant.
9. If desired or necessary, the control box can be mounted in
a semi-remote location.
a. Remove the control box from the bottom of the unit.
b. If necessary, remove the end brackets from the control
box, rotate and reposition them.
c. The remote control box can be panel, surface, under-
counter, or recess mounted. If recess mounting, The
control box will require a hole mounting pattern of
7-5/8″ W x 1-1/4″ H (194 mm x 32 mm) for #8 screws.
Figure 9. Remote Control Box Mounting Options
Recess
Panel
Under Counter
Surface
d. The distance the remote control box can be mounted
from the unit is determined by the 36″ (914 mm) conduit.
Do not pull the conduit tight to increase the mounting
distance. The conduit should have some slack after the
control box is mounted.
Do not modify wiring or cut thermostat capillary wire on
control box to increase-remote mounting distance. Cutting
the thermostat capillary wire will cause the unit to overheat
and may damage the unit as well as the surrounding
countertop.
10. Once all components are secured, proceed to the
OPERATION section.
NOTE: A 6′ (1829 mm) cord is supplied with this unit; any
excess cord should be neatly routed so it does not hang
down.