Required Tools
The following tools are required for installation
of the NovAseptic
®
GMP ATEX Mixer. The
tools (shown below) are
not
included with
the mixer and are available from your local
representative. Component catalog numbers
and specifications can be found on our web
site.
Description
Purpose
NovAseptic
®
Gauges 1
and 2
Checks the tank plate
deformation.
Multi tool
(GT#/25)
Installation tool for mixing
head and male bearing for use
in small vessels.
Tightening
tool
(GT#/26)
Installation tool for male
bearing.
Heatsink
tank plate
(G94-#)
Attached to the tank plate
during welding to prevent
deformation.
NovAseptic
®
gauge 1
(G91-#)
For verification of geometry
after welding.
NovAseptic
®
gauge 2
(G92-#)
Optional Equipment
Catalog numbers and specifications for the
component shown here can be found at www.
millipore.com.
Description
Purpose
Mixing head
attractor
(GT#/AW)
Keeps the mixing head in
place when vessel is moved.
Replaces the drive unit during
transport.
Installation and
Operating Parameters
Please refer to the appropriate product
specification sheet for more information.
Parameter
Minimum
Maximum
Tank Plate
Temperature
-80 °C
(-112 °F)
200 °C
(392 °F)
Pressure
-1 barg
(-14.5 psig)
10 barg
(145 psig)
Mixing Head, Male Bearing, and Tank
Plate
Defines the operating parameters inside the
vessel
Temperature
5 °C (41 °F)
135 °C
(275 °F)
pH
1
14
Viscosity
1 cP
800 cP
Media
Media may not contain
magnetic particles.
Rotation
speed
See Product Specification
Sheet.
Minimum
acceleration
and
deacceleration
time
Five seconds (specific to each
application; set accordingly).
Drive Unit
Defines the operating parameters outside the
vessel
Ambient
temperature
0 °C (32 °F) 40 °C (104 °F)
Noise Level and Vibrations
Motor noise levels are measured according to
ISO
®
1680 standard, and are within maximum
levels specified by standards IEC 60034-9.
Vibration falls under standard class N, as
specified by standard IEC 60034-14.
The noise level and vibration of the motor
installed in the tank must be evaluated before
the complete installation is declared compliant
with appropriate equipment directives.
NovAseptic
®