background image

P 3

Please retain product label and instructions for future reference

             

22

23

24

25

26

30

31

32

33

27

28

29

34

35

36

37

38

39

40

42

44

45

43

41

46

47

48

Starter Board - 28x66x2191mm

 

QTY 1

LB28RT66-AGRL-2191 (1x45 deg cut top, 1x45 deg cut bottom)

Log Board - 28x120x311mm

 

QTY 18

LB28-BGL-311 (1x45 deg cut left)

Log Board - 28x120x311mm

 

QTY 17

LB28-BGR-311 (1x45 deg cut right)

Log Board - 28x60x311mm

 

QTY 1

LB28-BH60GR-311 (1x45 deg cut right, 60mm height board)

Log Board - 28x70x311mm

 

QTY 1

LB28-BH70GR-311 (1x45 deg cut right bottom notch, 70mm height board)

Log Board - 28x120x2191mm

 

QTY 1

LB28-J-2191 (1x45 deg cut left, 1x45 deg cut right top notch)

Log Board - 28x120x2191mm

 

QTY 1

LB28-JD-2191 (1x45 deg cut left, 1x45 deg cut right top notch, door notch)

Starter Board - 28x66x1625mm

 

QTY 1

LB28RT66-AGL-1625 (1x45 deg cut left)

Log Board - 28x120x1625mm

 

QTY 6

LB28-AGL-1625 (1x45 deg cut left)

Log Board - 28x120x1625mm

 

QTY 1

LB28-J-1625 (1x45 deg cut left 50mm bottom notch)

Log Board - 28x120x1625mm

 

QTY 1

LB28-JDL-1625 (1x45 deg cut left 50mm bottom notch, window notch)

Log Board - 28x120x1625mm

 

QTY 1

LB28-JDR-1625 (1x45 deg cut right, window notch)

Log Board - 28x120x1625mm

 

QTY 7

LB28-AGR-1625 (1x45 deg cut right)

Finisher  Board - 28x64x1625mm

 

QTY 1

LB28-AH64GR-1625 (64mm high board, 1x45 deg deep cut right)

Finisher Board - 28x64x3000mm

 

QTY 1

LB28-AH64-3000 (64mm high board)

Starter Board - 28x66x3000mm

 

QTY 1

LB28RT66-A-3000

Log Board - 28x120x3000mm

 

QTY 40

LB28-A-3000

Finisher Board - 28x80x1945mm

 

QTY 1

LB28RG80-J-1945 (2x61 deg cut, 1945mm finished)

Finisher Board - 28x80x677mm

 

QTY 1

LB28RG80-CGR-677 (2x45 deg cut left,  677mm finished)

Finisher Board - 28x80x677mm

 

QTY 1

LB28RG80-CGL-677 (2x45 deg cut right, 677mm finished)

Finisher Board - 28x80x638mm

 

QTY 6

LB28RG80-C-638

Log Board - 28x120x439mm

 

QTY 24

LB28-B-439

Log Board - 28x120x439mm

 

QTY 12

LB28-BGL-439 (1x45 deg cut left)

Log Board - 28x120x439mm

 

QTY 12

LB28-BGR-439 (1x45 deg cut right)

Roof Truss - 40x140x922mm QTY 1

AI-06LOGC3X3-LRT-V1

Roof Truss - 40x140x922mm QTY 1

AI-06LOGC3X3-RRT-V1

Roof Truss A- 40x140x1604mm QTY 5

AI-06LOGC3RTA-V1

53

54

55

56

58

59

60

49

50

61

Bearer - 44x44x2808mm QTY 1

F4444-2808-PT 

Bearer - 44x44x2720mm QTY 6

F4444-2720-PT

Bearer - 44x44x2492mm QTY 1

F4444-G-2492-PT (1x45 deg cut, 2492mm finished)

Bearer - 44x44x2222mm QTY 1

F4444-G-2222-PT (1x45 deg cut, 2222mm finished)

Bearer - 44x44x1951mm QTY 1

F4444-G-1951-PT (1x45 deg cut, 1951mm finished)

Bearer - 44x44x2055mm QTY 1

F4444-G-2055-PT (2x45 deg cut, 2055mm finished)

Bearer - 44x44x1356mm QTY 1

F4444-G-1356-PT (1x45 deg cut, 1356mm finished)

Bearer - 44x44x1680mm QTY 1

F4444-G-1680-PT (1x45 deg cut, 1680mm finished)

52

Roof Truss B - 40x140x2225mm QTY 1

AI-06LOGC3RTB-V1

Roof Truss C- 40x140x1604mm QTY 1

AI-06LOGC3RTC-V1 (2X76 deg parallel cuts, 1x45 deg mid right) 

Roof Purlin - 45x120x1523mm QTY 1

F45120-B-1523

51

Roof Truss D- 40x140x1604mm QTY 1

AI-06LOGC3RTD-V1 (2X76 deg parallel cuts, 1x45 deg mid left) 

57

Bearer - 44x44x1399mm QTY 1

F4444-G-1399-PT (1x45 deg cut, 1399mm finished)

*If you are constructing a 5x3 cabin you will not need 

this part - see 5x3 instructions for correct part*

Summary of Contents for 0628CSNE0303HGDD2SW-V1

Page 1: ...where the building and base are going to be constructed Ensure that there will be access 60cm to all sides for maintenance work and annual treatment Ensure the base is level and is built on firm groun...

Page 2: ...QTY 1 Morticed for lock AI 06LOGDGMD750X1900 V3 13 14 15 17 17a 17c 18 19 20 21 Slave DoorQTY 1 AI 06LOGDGSD750X1900 V3 Door Frame Left Upright 71x70x2065mm QTY 1 AI 0628LOGDUFL V3 Door Frame Right Up...

Page 3: ...3000 Finisher Board 28x80x1945mm QTY 1 LB28RG80 J 1945 2x61 deg cut 1945mm finished Finisher Board 28x80x677mm QTY 1 LB28RG80 CGR 677 2x45 deg cut left 677mm finished Finisher Board 28x80x677mm QTY 1...

Page 4: ...63 Fascia 16x120x2225mm QTY 1 S16120 2225 Roof Board Pack B QTY 2 AI 06LOGC3X3RBP2 V2 Roof Board Pack C QTY 2 AI 06LOGC3X3RBP3 V2 73 64 Fascia 16x120x2000mm QTY 2 S16120 2000 65 66 Fascia 16x120x1658...

Page 5: ...x 12 70mm Screw x 85 70mm Bolt Set x 16 There may be extra screws present in the nail bag 80mm Screw x 24 Pre assembly Please note Each board interlocks at either end in a staggered pattern Before sec...

Page 6: ...ly assembled ensure the bearers are square by measuring from corner to corner as illustrate making sure they are an equal measurement If the bearers are not alligned equally unscrew and adjust and re...

Page 7: ...wn in the illustration 5x70mm Screws 70mm screw IMPORTANT Pre drill before fixing screws a b 40 36 22 41 32 1st 2nd 3rd 5th 4th 36 22 Step 4 Parts needed No 25 QTY 1 Make the log cabin level by adding...

Page 8: ...on Place the master and slave doors No s 9 10 onto a flat surface and fix the Adjustable door hinge No 17c to the doors using 3x30mm screws per hinge Fix 3 x Adjustable Door Hinges No 17a b into posit...

Page 9: ...slide the assembled door frame over the boards resting the frame on top of the starter board if you have not yet assembled the door frame refer to step 6 Please note This image is for illustrative pu...

Page 10: ...be postioned on the inside of the building Pre drill hole 30mm screw Step 12 Parts Needed No 1 QTY 2 No 7 QTY 4 Position the window No 1 so that it sits centrally within the window frame Fix the femal...

Page 11: ...thod as shown in the illustration bringing the board level to the top of the window and door frames Please note when you get to the top of the boards the right hand boards will be slightly lower Ensur...

Page 12: ...ush with each other as you lay each one Rubber Mallet may be required to fit parts Step 18 Parts needed No 38 QTY 1 No 39 QTY 1 Lay the Finisher Boards No 38 39 onto the front of the log cabin to brin...

Page 13: ...n Fix into position by screwing through the notches as shown in the illustration Ensure that the boards are level and flush with each other as you lay each one 2x120mm Screws Pre drill hole 120mm scre...

Page 14: ...crewing through the truss into the Purlin at an angle as shown in the illustration using 1x90mm screw per truss 3x90mm Screws Pre drill hole 90mm screw Rubber Mallet may be required to fit parts Pre d...

Page 15: ...fore fixing screws 48 48 48 Rubber Mallet may be required to fit parts Please note You can adjust the blocks attached to the roof truss if necessary IMPORTANT Pre drill before fixing screws Step 24 Pa...

Page 16: ...y 1 Roof Assembly 2 45 45 45 45 42mm 42mm Rubber Mallet may be required to fit parts 45 43 Step 26 Parts needed No 48 QTY 2 Locate the last two Roof Truss A No 48 into the 42mm gaps between the finish...

Page 17: ...ew Roof Assembly 1 Roof Assembly 2 IMPORTANT Pre drill before fixing screws 70mm screw 52 IMPORTANT Pre drill before fixing screws Step 28 Parts needed No 71 QTY 1 Pack A No 72 QTY 2 Pack B No 73 QTY...

Page 18: ...e 5 sides 84x40mm Screws Pre drill hole 40mm screw A B C B C 72 73 73 71 72 A B C B C 72 73 73 71 72 Roof Assembly 1 Roof Assembly 2 IMPORTANT Pre drill before fixing screws Step 30 Parts needed No 71...

Page 19: ...h screwed down in total on each of the 5 sides 84x40mm Screws A B C B C 72 73 73 71 72 A B C B C 72 73 73 71 72 IMPORTANT Pre drill before fixing screws Roof Assembly 1 Roof Assembly 2 Pre drill hole...

Page 20: ...m screw Step 34 Parts Needed No 8 QTY 2 Fix the casement stay No 8 onto the window No 1 and the casement stay pins to the window framing using 6x30mm screws Ensure the casement stay is centralised on...

Page 21: ...onmongery Neverthe less the process of fixing the frames is the same Once components have been fitted try closing doors to ensure the doors can be closed and the lock works If your doors do need adjus...

Page 22: ...2 4 5 6 7 8 Felt sheet dimensions 1 1600mm L x 1000mm W 2 2303mm L x 1000mm W 3 1655mm L x 1000mm W 4 3141mm L x 1000mm W 5 1600mm L x 1000mm W 6 820mm L x 1000mm W 7 680mm L x 1000mm W 8 2180mm L x 1...

Page 23: ...bearers 200x40mm Screws 40mm screw Pre drill hole This is for illustrative purposes only and may differ from your floor 70 70 IMPORTANT Pre drill before fixing screws Roof Closure Trim Internal 67 Me...

Page 24: ...cut to size in the same way as previously stated 34x40mm Screws Pre drill hole 40mm screw 63 64 64 65 65 65 62 Pre drill hole 70mm bolt 66 66 Step 44 Parts needed No 66 QTY 8 Arrange the storm braces...

Page 25: ...indow frame fixing in place onto the framing above each window using 3x70mm screws per guard Attach the Rain Guard No 16 to the door frame fixing in place onto the framing above the Door using 3x70mm...

Reviews: