Configuration
COMMAND LIST
CALLS
OF ALARM
PROG CONS
COMMENTS
Alarm
management
mode
*22#n *22*
n=0-2
0 (basic phone)
: All calls
are considered correct.
1 (EN 81-28 strict):
Alarm acknowledgement
(ACK) and end of alarm
(EOA) managed according
to standard.
2 (EN 81-28 practical):
Alarm acknowledgement
(ACK) according to
standard; no need to
generate EOA to close the
alarm
Default value: 2
Protocol of the
1
st
alarm phone
*42#n *42*
Communication protocol
used during alarm, test and
event calls. Each phone
number can be configured
with a different protocol:
n=0-1
0 (MERak Protocol):
From
the alarm receiving
equipment, any key is
pressed to establish voice
communication.
1 (P100): Simple and fast
communications
protocol
suitable for use in lift
emergency telephones. To
schedule calls with the
P100 it is necessary to use a
test call management
service that supports this
protocol.
Default values:
Alarm phone = 0
Test phone number = 1
Phone Events = 1
Protocol of the
2
nd
alarm phone
*43#n *43*
Protocol of the
3
rd
alarm phone
*44#n *43*
Protocol of the
4
th
alarm phone
*45#n *45*
Protocol of the
1
st
test phone
*46#n *46*
Protocol for the
2
nd
test phone
*47#n *47*
Event phone
protocol
*48#n *48*
26
MEP2L M3.0-S1.4 EN
2020 Merak Telsis SL. All rights reserved
!