DEFAULT VALUES
Some variable features have default settings which
are enabled immediately after RESTORE DE-
FAULTS is commanded from the front panel, or a
DEFAULT command is issued over a remote bus.
The resulting default values are listed below:
Table 3.1 - Default Values
TRANSDUCER
The highest full scale range transducer in the sys-
tem used for pressure control will be an internal
transducer. This is designated as the primary
transducer, and is assigned address 0. The
pressure regulator is configured based on the pres-
sure range of this transducer, and no other internal
transducer can be of a higher pressure range than
the primary. Throughout this manual the terms
‘sensor’ and ‘transducer’ are used interchangeably
unless specifically defined.
Address
The addresses for internal transducers are as-
signed at the factory and should not be changed.
The serial number, address and range of each
transducer is recognized by the
PCS 400
. These
identity features are displayed on the front panel
for the transducer under LIMITS on the menu tree.
To see the active transducer identity in the display
use the key sequence: [2nd] [3] [=] .
To view information about other transducers con-
nected to a multi-range system press [+] [+] ... [+]
which will scroll the display to the next higher
address transducer, and on, through the full
transducer list. When the highest address internal
transducer of a multi-range unit is displayed the
next [+] will present the
AUTORANGE
screen.
To exit without affecting the current active
transducer status press [CE].
Feature
Standard PCS 400
With HPCU
Option Installed
Engineering Units
PSI
same
Active Sensor
Address 0
same
Autorange
ON (only for multiple internal sensors)
same
Emulation Mode
OFF (defaults to native gauge or abs measurements)
same
Resolution
7 characters
same
Display
Pressure (not Rate or Peak)
same
Remote Ports
IEEE port initialized
same
Measure Filter Percent
**
90%
same
Measure Filter Window
0.025% FS
0.01%
Control Stable Window
*
0.004% FS
0.02%
Control Stable Delay
67 readings
200 readings
Control Mode
Normal (not Rate or External)
Pressure Step
0 (no response to [+] or [-] in Control Mode
*
(Control Stable Window Default is 0.008% for FS < 2 psi)
**
(Filter Percent is 98% for FS <2 psi) and (95% for >2 to <10 psi)
PCS 400
LOCAL OPERATION
www.mensor.com
3-7
Summary of Contents for PCS 400
Page 13: ...User s Notes TABLE OF CONTENTS PCS 400 xii www mensor com ...
Page 23: ...User s Notes INSTALLATION PCS 400 2 4 www mensor com ...
Page 41: ...User s Notes LOCAL OPERATION PCS 400 3 18 www mensor com ...
Page 73: ...User s Notes SPECIFICATIONS PCS 400 7 4 www mensor com ...
Page 115: ...User s Notes INDEX PCS 400 10 6 www mensor com ...
Page 116: ......