background image

Page 4 of 8

Data Sheet CPC3000

Touch screen operation

Main screen

The CPC3000 main operation screen appears after powering up the unit. This screen contains all of the controls needed to 

navigate within the menus and to operate the instrument. The setup icon button opens up a menu that provides navigation to all 

the set up screens, limits indication, tab selectable input menu, set point display and selection, pressure value indication, pressure 

units indication and selection and measure / control / vent mode selection. 

MEASURE

Measure mode pneumatically connects 

the pressure sensor directly to the device 

under test. In measure mode pressure 

regulation is inactive. 

CONTROL

In the control mode, the device 

regulates the pressure output 

according to the set point value, 

providing a precise pressure at 

the test port.

VENT

Vent mode vents the system and the 

device under test to atmospheric 

pressure.

Optional information can be displayed in the main menu by selecting the option in the setup menu 

User defined DUT / control range limits 

(configurable via SETUP)

* optional display element

Numeric keypad

 Delete selected set point

 Delete last entered digit

 Accept selected set point

Setup Icon Button

Entered set point

Stable indication

Current pressure value

Pressure unit and mode

Bar graph

Mode

SETUP menu

The SETUP menu allows configuration 

of the following points:

 

„

Language (17 currently available)

 

„

Maximum control range

 

„

Step and Jog functions

 

„

Interface setting

 

„

Display of additional information

SETUP 

menu

Communication status*

Optional barometric refer-

ence display*

 

        Jog key pad selection tab

 

User defined Jog

        Step key pad selection tab

Numeric key pad selection tab

Note: See the following page for detailed information on 

each set point entry screen.

Summary of Contents for CPC3000

Page 1: ...tion facility all screens can be viewed in several different languages To enter the pressure setpoint the operator can choose between four input modes which can be selected using the corresponding tab The input modes are 1 The numeric key menu provides a way to enter a specific pressure set point value to be controlled 2 The step keypad menu provides defined steps programmed in pressure increments...

Page 2: ...Barometer Port Exhaust Relief Port 12 3125 Page 2 of 8 Data Sheet CPC3000 Dimensions in inches Rear view Front view Side view Fan On Off switch Fuse Power supply Electrical connections and pressure ports rear view 10 1875 8 6875 5 5 7 375 Ethernet IEEE 488 USB ...

Page 3: ...mH2O 4C mmH2O 20C cmH2O 20C mH2O 20C Pressure units user defined 2 multiplier from psi or Pascal Slew rate 3 seconds to stable flag 0 025 full scale pressure for a 10 pressure change typical into 150cc volume at pressures greater than 5 PSI Larger volumes can lengthen this time Controlling to pressures less than atmosphere can lengthen this time Overshoot 1 FS in high speed mode Control stability ...

Page 4: ...ding a precise pressure at the test port VENT Vent mode vents the system and the device under test to atmospheric pressure Optional information can be displayed in the main menu by selecting the option in the setup menu User defined DUT control range limits configurable via SETUP optional display element Numeric keypad Delete selected set point Delete last entered digit Accept selected set point S...

Page 5: ...ypad have values which correspond to the 3 last digits of the pressure reading and are used to incre ment the set point Triangles pointing up will increase the value and those pointing down will decrease it The smallest triangle increments the least significant digit by one the medium size triangle increments the least significant digit by ten andThe large triangle increments the least significant...

Page 6: ...ter the setpoint value and press The controller will then ramp up the setpoint 0 20 40 60 80 100 Percent of Setpoint Steps changed at operator discretion Setpoint entry using the step keypad step changes automatically calculated as a percent of the user defined full scale limit and indicated in percent FS or pressure units can be entered by pressing step keys in any sequence Setpoint entry using j...

Page 7: ...mand structures In addition to IEEE 488 the CPC3000 has Ethernet and USB communications making it remotely accessible to today s modern automation systems Trouble shooting the initial remote setup is made easy by viewing the remote monitor which displays the most recent commands sent and responses from the CPC3000 plus any error messages Options and accessories Barometric reference An optional bar...

Page 8: ...y CPC3000 High Speed Pressure Controller Desk top version with bezel and handle Power cable 6 ft with plug Operating instructions NIST traceable calibration certificate Pressure adaptor fittings A2LA certificate Options Barometric reference 19 rack mounting kit Customized calibration system Accessories Additional pressure adaptor fittings All standard Mensor products are provided with a calibratio...

Reviews: