![Mennekes AMTRON Premium User'S Operation Manual Download Page 61](http://html1.mh-extra.com/html/mennekes/amtron-premium/amtron-premium_users-operation-manual_1770859061.webp)
26
Value
Description
Power Fail
Continue
Enable / disable continue charging
process after power failure
The charging process continues after
a power failure
A power failure terminates the
charging process
Autostart
Charging
Enable / disable autostart of charging
process
The charging process starts
automatically when connected to a
vehicle.
The charging process must be
started manually when connected to
a vehicle.
This setting will be ignored with
RFID card reader enabled.
Enable Stop
Button
Enable / disable stop button.
Stop button enabled
Stop button disabled
Color Schema
Setting the colour scheme of LED info
bar
Enable RFID
Beep
Enable / disable audible feedback of the
RFID card reader.
Audible feedback enabled
Audible feedback disabled
Enable WLAN
Communication
Enable / disable WLAN module.
WLAN module enabled
WLAN module disabled
AMTRON
Operation
Mode
Selecting the operating mode of the
charging station.
Value
Description
STA SSID
Name of the WLAN the charging station
is connected to.
STA Connected
Status of the WLAN connection.
true: Charging station is connected
to a WLAN
false: No connection of the charging
station to a WLAN
STA Security
Mode
Selecting the WLAN encryption.
Default setting: "Autodetect security
mode"
STA Security
Key
Entering the WLAN security key.
AP Security
Mode
Selecting the WLAN encryption when
charging station is operated in access
point mode.
AP Channel
Selecting the WLAN channel when
charging station is operated in access
point mode.
AP Country
Code
Selecting the country code when
charging station is operated in access
point mode.
Local
Timestamp
Display / enter the current system time
of the HC controller in Unix timestamp
format.
Currently
Summer
Selecting daylight saving time / standard
time
Daylight saving time
Standard time
Timezone
Offset
Enter the difference between the local
time zone and UTC time in minutes.
SW Reset
Software reset
Click on the button "
Reset
" to restart
the HC controller of the charging
station.