Description of operating modes
Functional description of
manual
operating mode (remote)
Start of charging
process
Without RFID card:
Automatically after connection to the vehicle
Manually with Charge APP
With RFID card:
Authentication with valid RFID card
Manually by selecting a valid RFID card in Charge APP
Controlling the charging
process
By using the Charge APP
Changing the charging current for the on-going charging process
Interrupting the charging process (pause)
Continuing the charging process
Terminating the charging process (stop)
By using the multi-function button:
Terminating the charging process (stop)
The stop function with the multi-function button must be enabled during the setting-up
process.
With RFID card:
Terminating the charging process (stop, with the same card used for starting the charging
process)
In operating mode "
manual
", all functions of other operating modes are suspended. The
charging power, for example, will not be controlled over time, the external tariff-switching
signal or the "SUNNY HOME MANAGER".
Changing the operating
mode
The Charge APP or service interface allows changing the operating mode configured during the
setting-up process. The change of operating mode will apply for the on-going and subsequent
charging processes.
Response to power
failure
The response to power failure is configured during the setting-up process.
The charging process is aborted (default with authorisation enabled).
The charging process is continued (default for automatic start).