85-03-00955
P a g e
|
20
2 7/16
3 7/8
31 3/16
NON-COMBUSTIBLE ZONE
Cross-Hatched Areas around Glass
Frame requires non-combustible
facing.
MANTEL
NON-COMBUSTIBLE ZONE
12
46 9/16
35 1/16
SAFETY BARRIER
All decorative fronts that can be mounted on the ML39 Fireplace are certified Safety Barriers. If the Fireplace is installed
without a decorative front then the Safety Barrier part number AA-11-02117 must be installed on the Fireplace. The Safety
Barrier will mount on the glass frame of the fireplace. Follow the instruction manual with the Safety Barrier for installing the
Safety Barrier. Never operate the fireplace without a certified Safety Barrier installed on the fireplace. Only use Mendota
approved fronts with this fireplace.
NON-COMBUSTIBLE FINISHING MATERIALS REQUIREMENTS
WARNING: The cross hatched areas labeled as “NONCOMBUSTIBLE ZONE” must be covered with noncombustible fin-
ishing materials that is 1-inch thick, minimum unless Adjustable Framing Brackets are utilized. (See section on Adjustable
Framing Brackets for more information.) DO NOT ALLOW COMBUSTIBLE MATERIALS TO ENCROACH IN THIS
AREA!