85-03-01205
ML-SERIES FIREPLACE
Page
17
3.2.5
ML-SERIES Fireplace Ratings Information
This Mendota Fireplace can be installed directly on top of a metal, masonry, or wood structural surface.
ELECTRICAL REQUIREMENTS
: 120 Volts AC, 3.5 Amps (minimum line voltage allowed 110 Volts AC) REQUIRED
GAS SUPPLY PRESSURE
:
NAT. GAS: 7" W.C. [5.0" W.C. MIN., 11" W.C. MAX.]
L.P. GAS: 11" W.C. [11" W.C. MIN., 13" W.C. MAX.]
LP GAS CONVERSION KIT
: This Fireplace comes configured for use with Natural Gas.
MODEL
NAT. GAS
INPUT
RATE (HIGH
FIRE)
NAT. GAS
INPUT
RATE (LOW
FIRE)
LP GAS
INPUT
RATE (HIGH
FIRE)
LP GAS
INPUT
RATE (LOW
FIRE)
ORIFICE SIZES
(0-2000 ft)
ORIFICE SIZES
(2000-4500ft)
P.4
FIREPLACE
EFFICIENCY
LP Kit
Part #
ML39
34,250
23,000
34,250
28,000
#33 NG [#50 L.P.]
#34 NG [#51
L.P.]
76.2%
HA-
96-
00023
ML47
41,000
25,000
41,000
24,000
1/8” NG [#4
8 L.P.]
#31 NG [#49
L.P.]
70.8%
HA-
90-
00110
ML54
41,000
27,500
41,000
33,000
1/8” NG [#49 L.P.]
1/8” NG [#49
L.P.]
70.7%
ML60
41,000
27,500
41,000
33,000
1/8” NG [#49 L.P.]
1/8” NG [#49
L.P.]
72.7%
ML72
60,000
27,000
60,000
31,000
F: #30 R: #43 NG
[F: #46 R: #54] LP
F: #30 R: #43 NG
[F: #46 R: #54] LP
80.8%
HA-
112-
00061
FLUE VENTING
............COAXIAL RIGID- 5
” DIAMETER EXHAUST &
8
” DIAMETER
AIR INLET AND APPROVED VENT CAPS
APPROVED FOR USE WITH MENDOTA POWER VET KITS AA-11-04071, AA-11-04072, and AA-11-04100.
All UL Listed Coaxial Rigid 5”X8” Vent pipe components and vent caps are approved for use. Do not mix components of
different brands or series. Always use the same brand and series components throughout the entire vent system.
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
UNIT TO FLOOR
0in. (0mm)
UNIT TO ENCLOSURE SIDEWALL
1/2in. (13mm)
UNIT TO ENCLOSURE BACK WALL
1/2in. (13mm)
UNIT BOTTOM TO ROOM CEILING
72 in. (1829 mm)
UNIT SIDE TO ADJACENT SIDEWALL
18in. (457 mm)
VENT PIPE TOP TO COMBUSTIBLES
3in. (76mm)
VENT PIPE SIDES TO COMBUSTIBLES
1in. (25mm)
VENT PIPE BOTTOM TO COMBUSTIBLES
1in. (25mm)
DISTANCE TO 8” MANTEL ABOVE TOP CONVECTION AIR DISCHARGE OPENING
20 in. (508 mm)
MINIMUM COMBUSTIBLE ROUGH FRAMING DIMENSIONS
MODEL
WIDTH
HEIGHT
DEPTH
UNIT BOTTOM TO
ENCLOSURE CEILING
ML39
56
40
19 1/2
60
ML47
62
42
19 1/2
62
ML54
69
44 1/2
19 1/2
64 1/4
ML60
75
44 1/2
19 1/2
64 1/4
ML72
86
46
19 1/2
54
NET WEIGHT
................250-500 lbs. (Team Lift recommended)
BARRIER SCREEN
: A barrier screen that has been certified for use with this Fireplace must be installed on the Fireplace when it
is in use. The barrier screen will prevent accidental contact with the glass door face, which could result in a severe burn.
SAFETY
: AGA certified, electronic ignition IPI system activated with thermostatic remote control.