3.3
ELECTRICAL TECHNICAL REFERENCES
3.3.1
AC Power Requirements
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
When this appliance is installed with a three-prong (grounding) plug for protection against shock hazard, it should be plugged
directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from the plug.
For normal operation, this appliance requires 120 VAC, 2 Amp power or a 6V DC power source. The AC power
supply to this fireplace Insert must be hot at all times and shall not have a switch installed in it.
This appliance is equipped with an electrical junction box on the right
side and a 6V DC power inlet connector located directly below the
master switch on the right side, adjacent to the glass frame’s right
edge.
Planning for AC Power Connection
On the right-side of the insert, there is an electrical junction box with a
strain relief clamp. The insert comes with a cord wired to the insert. If
the insert is going to be hard wired the cord can be removed.
The insert comes with the cord exiting on the side of the insert. If an
installation does not allow room on the side for the electric cord the
cord can be rerouted through a hole in the rear of the insert.
Electrical Junction Box