background image

1 of 28

ENG

May 2022

OPERATION AND INSTALLATION MANUAL

MULTI-FUEL & SMOKE EXEMPTION MODELS

Churchill 5 SE MK5 Dual Control

Churchill 5 Convec�on SE MK5 Dual Control

Churchill 5 Convec�on Logstore SE MK5 Dual Control

CHURCHILL DC Mk.5 Manual - Version 1.1 - May 2022

Summary of Contents for Churchill 5 SE MK5 Dual Control

Page 1: ...AND INSTALLATION MANUAL MULTI FUEL SMOKE EXEMPTION MODELS Churchill 5 SE MK5 Dual Control Churchill 5 Convec on SE MK5 Dual Control Churchill 5 Convec on Logstore SE MK5 Dual Control CHURCHILL DC Mk...

Page 2: ...MENSIONS AND CONNECTION MEASUREMENTS THE INTERNAL DIAMETER OF THE FLUE COLLAR IS 125mm 505 614 37 327 343 512 10 130 388 39 80 50 71 CHURCHILL RADIANT CHURCHILL CONVECTION 549 614 343 327 130 512 50 8...

Page 3: ...el and provides addi onal radiant protec on from the flue collar CHURCHILL CONVECTION LOGSTORE 549 537 549 343 327 130 388 678 216 80 780 817 427 39 66 37 STOVE DIMENSIONS AND CONNECTION MEASUREMENTS...

Page 4: ...ring your Mendip Stove within one month of the la er of the purchase date or installa on on date Accordingly the start date for the warranty period is the date of purchase During the registra on on pr...

Page 5: ...e the stove to emit fumes into the room Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the coarse of installa on then please seek specialist guidance...

Page 6: ...Registered smoke exempt models with a 125mm collar burning wood only can be installed on a flue of 125mm throughout Any bend in the chimney or connecting flue pipe should not exceed 45 90 bends should...

Page 7: ...the stove this slots over the rear Convection panel providing addi onal radiant protec on from the flue collar A twin wall insulated flue should be fi ed flush to the flue collar for this type of inst...

Page 8: ...Dual Control Convec on Model INSTALLING THE CHURCHILL CONVECTION IN A CORNER POSITION Churchill 5 Dual Control Convec on Model Pictured on a 1000mm wide and 1000mm deep glass teardrop floor plate 150m...

Page 9: ...nt air flow available to it during opera on please allow at least 40mm of clearance from the back of the air intake to the rear wall This means that if you are installing your stove between 50mm and 1...

Page 10: ...allation protect paint with a blanket 1 Remove internals and top plate 2 3 4 5 Unbolt stove adjustable legs with 13mm spanner Use M8 x 50mm bolts supplied and fix legs in place use 13mm spanner to tig...

Page 11: ...aning the stove Any defec ve panels should be replaced small hairline cracks do not need replacement however these can develop during long term use to a larger crack if this passes through the vermicu...

Page 12: ...uids Ligh ng your stove with firelighters will be more reliable and easier than using paper Ligh ng your fire with paper results in excess smoke more ash and possible blackening of the glass LIGHTING...

Page 13: ...s condensa on on the door glass 4 Once the flames from the logs are fully established this can take up to 10 min s The door can now be closed Slide the Primary air inwards to the closed posi on If the...

Page 14: ...se as firewood it should be stacked and air dried under cover for two years before being used as firewood Do not burn liquid fuels dri wood finished sawn wood pallet wood chipboard plywood varnished w...

Page 15: ...the chimney Adding fuel to your stove when you only have glowing embers and the flames have died down is the cleanest way to refuel your stove 1 Before refuelling Pull open both the Primary and Second...

Page 16: ...overnight or for long periods una ended see Overnight Burning To Re fuel Your Stove Using Solid Fuel 1 Your stove will need to be refuelled approximately every 2 hours see page 6 2 Before refuelling...

Page 17: ...ove is completely cold before cleaning out ash embers can remain hot for over 24 hours Ash must be stored in a non Combustible container and must not be mixed with other Combustible waste Annual servi...

Page 18: ...an contact them for details of Clean Air Act requirements The Churchill 5 SE Dual Control MK5 stove has been recommended as suitable for use in smoke control areas when burning wood logs The appliance...

Page 19: ...c on manual service record card warranty card 6 Vermiculite brick linings these are integral to the stoves performance Do not throw away 7 Top flue rear convec on panel 8 Moisture absorbency bag 9 Ash...

Page 20: ...t the 2 base bricks next to the grate Remove the le hand vermiculite side brick by Li ing the top baffle brick and pulling the side brick down from the top To remove the upper steel baffles turbulence...

Page 21: ...et Churchill 5 8 1 ES 500 412 1 Rear Brick 1 2 ES 500 413 1 Baffle Brick 1 3 ES 500 414 1 Right Side Brick 1 4 ES 500 415 1 le Side Brick 1 5 ES 500 417 1 Base Brick Side 2 6 ES 500 417 2 Base Brick R...

Page 22: ...22 of 28 STOVE PART NUMBERS 1 14 13 5 4 12 6 17 7 12 18 11 15 10 9 8 16 4 3 2 See Page 20 See Page 24 32 31 33 35 34 36 37 38 38 38 29 19 21 20 22 23 24 25 26 27 28 30 39 40 41 42 43...

Page 23: ...23 of 28 STOVE PART NUMBERS...

Page 24: ...0 Glass Clamp 3 CH 500 201 0 Door Frame only 4 M90502 01 01 99 03 Glass bowed 5 M90520 06 02 01 05 Door Rope Seal Kit 6 M90520 06 13 99 02 Handle Fixing Kit 7 M90026 01 02 01 04 Glass Seal Kit incl 6...

Page 25: ...04 AC2007 Essential characteristics Performance Fire safety Reaction to fire Al Distance to combustible materials Minimum distances in mm Rear 75mm Side 350mm std Side with flat convector panel 250mm...

Page 26: ...26 of 28...

Page 27: ...27 of 28...

Page 28: ...99 00 Mendip Stoves Ltd Unit H1 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Website www mendipstoves co uk Email info eurostove co uk Telephone 01934 750 500 CHURCHILL DC Mk 5 M...

Reviews: