![Mendip Stoves Churchill 5 SE MK5 Dual Control Operation And Installation Manual Download Page 7](http://html1.mh-extra.com/html/mendip-stoves/churchill-5-se-mk5-dual-control/churchill-5-se-mk5-dual-control_operation-and-installation-manual_1770733007.webp)
7 of 28
Log Length
Wood Reload
Weight Wood Load
smokeless brique�ed
fuel Reload
Weight smokeless
brique�ed fuel
Churchill 5
35cm
1hr
1.2kg
2hr
1.5kg
A DIAGRAM TO
ILLUSTRATE THE
MINIMUM DISTANCE
TO COMBUSTIBLE
MATERIALS
STOVE PERFORMANCE & TESTING
Combustible materials should not be located where the heat dissipating through the walls of fireplaces or flues
could ignite it. Therefore when installing the stove in the presence of Combustible materials due account must
be taken of the guidance on the separation of Combustible material given in Building Regulations Approved
Document J and also in these stove instruc�ons. The minimum distances to flammable materials are specified
on the EN 13240 plate on the back of the stove.
When installing the stove 7 5 mm from a combus�ble wall
behind , use the addi�onal, top flue rear convec�on panel
supplied with the stove, this slots over the rear
Convection panel providing addi�onal radiant protec�on from the flue collar.
A twin wall insulated flue should
be fi�ed flush to the flue collar for this type of installa�on
.
THE MINIMUM DISTANCE TO COMBUSTIBLE MATERIALS
Weight & Nominal Heat Output for Wood and Smokeless Fuels
Mendip Stoves, Churchill Dual Control 5kW models are tested in accordance with EN 13240.
158
350
7
5
3
8
7
6
0
0
20
°
Churchill 5 Dual Control
Standard Model
Pictured on an 800mm wide and
850mm deep floor plate.
0.08%
Distance to
Combustibles
Rear
Optional Side
flat convection
panels
Side
Round convection
panels
Logs placed in
logstore
Corner position
12mm non-
combustible
floor plate
Churchill 5 DC
75mm
250mm
N/A
Yes, with
additional
convector panel
150mm when
fitted with flat
side convectors
YES
Churchill 5 DC
Convection
75mm
N/A
150mm
Yes, with
additional
convector panel
100mm
YES
Churchill 5 DC
Convection
Logstore
75mm
N/A
150mm
Yes, convector
panel fitted as
standard
100mm
YES
250mm when
fitted with flat
side convectors
76.5%
17
135
61
4.9 kW