3 of 28
The
direct air intake spigot
(80mm diameter) to
the rear of the stove is removable with a 2.5mm
Allen key.
**
The addi�onal, top flue rear convec�on panel (supplied
loose within the stove) needs to be used when installing
the stove 100mm from a combus�ble wall; this slots over
the rear convec�on panel and provides addi�onal radiant
protec�on from the flue collar.
CHURCHILL CONVECTION LOGSTORE
**
549
537
549
343
3
2
7
130
388
6
7
8
2
1
6
8
0
7
8
0
8
1
7
427
39
66
3
7
STOVE DIMENSIONS AND CONNECTION MEASUREMENTS
THE INTERNAL DIAMETER OF THE
FLUE COLLAR IS
125mm
53mm DEFRA STOP (25 % 11mm reduction)
136mm MAXIMUM OPEN POSITION
89mm CLOSURE POSITION NO DEFRA STOP
104mm CLOSURE POSITION WITH DEFRA STOP
The SE appliances include a modified air control to prevent closure of the secondary air control beyond 25% open