To change output current intensity:

 Press the 9 function key(+) to 

increase current intensity or press the 6 function key(-) to decrease the 

current intensity. Or press the Number SET key until the edit cursor has 

moved to the output current position, and then use the number keys or 

arrow keys to change the value. 

 

To change polarity: 

the 4 function key (POL) to cycle through the output 

polarity between ± (alternating), + (polarized positive) and – (polarized 

negative). 

 

To change waveform

: Press the 7 function key (WF) to cycle through the 

list of predefined waveforms or use the UP/DOWN arrow keys. 

 

To change period

: Press the Number SET key until the edit cursor has 

moved to the digits for the period (02500ms), then enter the numbers or 

UP/DOWN arrow keys to change the digits of number. 

 

 

 

Summary of Contents for IS02PRO

Page 1: ...MEND ProfessionalTM IS02PRO Owner s Manual Ver 1 0 2016 3 4...

Page 2: ...4046 2016 MEND Technology LLC All rights reserved MEND Technology and the logo are the trademarks of MEND Technology LLC Trademarks or registered trademarks are the property of their respective holder...

Page 3: ...unning 13 Install Batteries 13 Connect Wires to IS02PRO 14 Connect Wires to Gloves Strips or Electrodes 14 Basic Operations 15 Power ON 15 All Recent and History Protocols 15 Select a Protocol 16 Run...

Page 4: ...e used for the relief of pain This device generates low intensity current pulses at microampere level and frequency of pulses Your licensed health care practitioner is able to program frequency pairs...

Page 5: ...ient Do not immerse the device into water Do not use the device close to flammable mixtures or concentrated flammable fumes such as gasoline The device can only be opened and repaired by the manufactu...

Page 6: ...practitioner The MEND ProfessionalTM has no curative value The MEND ProfessionalTM is a symptomatic treatment and as such suppresses the sensation of pain which could otherwise serve as a protective...

Page 7: ...is no warranty of merchantability nor of fitness for a particular use The Product is marketed under section 510 K of the Federal Food Drug and Cosmetic Act as a device substantially equivalent to a de...

Page 8: ...doctor or MEND Technology If necessary send the entire unit with the carrying case and accessories insured postage prepaid and well packaged along with the Return Merchandise Authorization number obt...

Page 9: ...nu selection protocol information active protocol parameter information and status are displayed on the LCD screen Protocol Running Control Press the START ON key to turn on the unit or to start a sel...

Page 10: ...to finish entering numbers or parameters In Manual Run Mode use the Number SET key to enter the CH1 and CH2 frequencies after they are selected on the number pad Protocols Press this key to cycle bet...

Page 11: ...ils 2 2 Rear Panel Separated Channel Jacks CH1 Jack positive and negative of CH1 CH2 Jack positive and negative of CH2 Combined Channel Jacks Positive Jack Positives of CH1 and CH2 Negative Jack Negat...

Page 12: ...w Negative Jack Tip CH2 Blue Ring CH1 Green Separated Channel Output Jacks CH1 Jack Tip CH1 Red Ring CH1 Yellow CH2 Jack Tip CH2 Blue Ring CH2 Green Table 1 Color Mapping of Output Jacks to Wire Conne...

Page 13: ...tall Batteries The MEND ProfessionalTM uses two alkaline batteries in size AA Remove the batteries if device is not going to be used for more than one month Note DO NOT use rechargeable Lithium Ion ba...

Page 14: ...es instead of holding the fiber part of the gloves to avoid damage to the gloves The mesh gloves and electrodes are intended for single patient use Conductive materials and strips can be easily cleane...

Page 15: ...y used Use Recent Protocols to quickly select your most frequently used protocols History Protocols lists the actual protocol running history The latest used protocol is displayed on the top of the li...

Page 16: ...s For example to select protocol number 215 of the 345 protocols press key2 key1 and key5 protocol 215 will be selected Browse to select protocol Use arrow UP DOWN keys to browse through the protocol...

Page 17: ...r and press START to continue running Stop the Therapy Protocol You can press the STOP key to stop running a protocol at any time Turn on the Back Light To turn on the LCD back light press Back Light...

Page 18: ...for 3 seconds the light will be turned on for 30 seconds Turn power off Press STOP OFF key to turn off the MEND ProfessionalTM The unit will power off automatically if the unit is not in use for 60 s...

Page 19: ...onductive material The common problems are loose plugs plugs are not inserted the button or push pin is not inserted into gloves or electrodes dry skin contact needs moisture or broken wires The devic...

Page 20: ...s of the new frequency value For example to enter 52 9Hz press CH2 then 5 2 9 and SET To change output current intensity Press the 9 function key to increase current intensity or press the 6 function...

Page 21: ...T and T to increase and decrease by 1 minute while the protocol is running To HOLD on a frequency pair press the 5 function key HLD to hold on the frequency pair The timer will hold however there wil...

Page 22: ...nu Next press the RIGHT arrow key to enter into manual run mode Default Manual Run Mode parameters The default Manual Run Mode screen will appear You can run immediately by pressing START or change th...

Page 23: ...w keys to change the value To change polarity the 4 function key POL to cycle through the output polarity between alternating polarized positive and polarized negative To change waveform Press the 7 f...

Page 24: ...quency pair press the 5 function key HLD to hold on the frequency pair The timer will hold however there will still be microcurrent flowing at the outputs Press HLD again to resume the timer To stop r...

Page 25: ...key until the edit cursor has moved to the ON OFF of key beeping use UP DOWN to change the value Press SET again when the new value is set To turn ON OFF protocol end beeping press SET key until the e...

Page 26: ...h is number 6 on the Main Menu Next press the RIGHT arrow key to enter into the About Version shows the hardware and firmware information Battery Status shows the battery voltage and estimated time th...

Page 27: ...n There is a quick test Put two gloves or all electrodes together If CH1 CH2 LEDs stop flashing it means the previous problem was caused by dry skin or poor contact You need to make remoisten the cond...

Page 28: ...rs 9191 R G Skinner Pkwy Unit 104 Jacksonville FL 32256 Operations 10117 SE Sunnyside Rd Suite F40 Clackamas OR 97015 Toll free 855 445 3971 Direct 503 594 4045 Fax 503 594 4046 Copyright 2016 MEND Te...

Reviews: