Functional Description
Page 33
3.2
System Management
The system is managed using an internal shelf controller with the following main
functionality:
Signaling system status to the application software
-
External voltage status
-
Power supply failures
-
Power supply voltage levels
-
Temperature
-
Fan speed and status
Fan control based on temperature
Forced system shutdown in case of
-
abnormal temperature
System start delay if
-
temperature too low
In normal operation you do not have to make any changes in the configuration.
3.2.1
Control Panel LEDs
The status of the MH70S is signalled using LEDs at the front of the system. The following
table shows the function and behavior of the LEDs.
Table 5.
Control panel LEDs
See the
for more information on the AF2 shelf controller.
The shelf controller supervises the system.
The board management controller supervises the CPU board.
Appearance
Label
Color
Function
Sys Status
Green
Blinking slowly: soft-off or waiting
until start condition satisfied
Blinking fast: system is shutting down
On: normal operation
Off: shelf controller powered off
Sys Status