Hardware Installation
Memotec Inc.
3-37
3.10.3
Activating the Console Connection
►
To activate the console connection:
1.
Ensure that the SDM-9XXX Series unit has successfully powered up with no system
status errors (see
“System Status on Power-Up” on page 3-32
).
2.
Power the console terminal on or start your console terminal emulation program.
Take note of:
“Important Console and Modem Settings for Startup” on page 3-36
3.
When you see the prompt
Type <ENTER> to connect
, press the
<Enter>
key on the
console terminal keyboard several times, until the SDM-9XXX Series unit responds
with a prompt for the user login.
4.
Enter the administrator login:
ADMIN
.
This is the default login. Additional user logins can be defined. Refer to the
NetPerformer Reference Guides
for details.
5.
Enter the password for this login.
When the password is entered correctly, the SDM-9XXX Series unit sends the
product banner to the console screen, as in this example:
LOGIN:ADMIN
PASSWORD:*****
ACCEPTED
SDM
‐
9230
vx.x.x
Memotec
Technologies,
Inc.
(c)
2007
Signaling
Engine
x.x.x
DSP
code
version:
x.x.x
Console
connected
on
port
CSL
B327091>
NOTE:
The default password for the administrator login is
SETUP
. Consult the
NetPerformer Reference Guides
for instructions on how to change or remove the
user password, if desired.
6.
Enter the Display Alarms (
DA
) command at the NetPerformer console command line
to verify that your unit is problem free. In particular, look for any alarm messages that
indicate
Call Technical Support
.
Summary of Contents for NetPerformer SDM-9120 Series
Page 1: ...NetPerformer Hardware Installation Guide SDM 9120 9220 9230 9140...
Page 10: ......
Page 68: ...NetPerformer Hardware Installation Guide 3 40 Memotec Inc...
Page 116: ...NetPerformer Hardware Installation Guide 4 48 Memotec Inc...
Page 132: ...NetPerformer Hardware Installation Guide 6 6 Memotec Inc...
Page 138: ...NetPerformer Hardware Installation Guide A 6 Memotec Inc...
Page 143: ...Memotec Inc B 5 Compliance and Regulatory Statements EU Directives EMC Safety RoHS...
Page 144: ...NetPerformer Hardware Installation Guide B 6 Memotec Inc...
Page 145: ...Memotec Inc B 7...
Page 152: ...NetPerformer Hardware Installation Guide B 14 Memotec Inc...
Page 157: ...Memotec Inc B 19 Compliance to China RoHS...
Page 160: ...NetPerformer Hardware Installation Guide B 22 Memotec Inc...