Rack Mounting and Servicing
When this product is mounted or serviced in a rack, special precautions must be taken to ensure that the system remains stable.
In general you should fill the rack with equipment starting from the bottom to the top.
Equipment Installation
This equipment should be installed, replaced, and/or serviced only by trained and qualified personnel.
Equipment Disposal
Disposal of this equipment should be in accordance to all national laws and regulations.
Local and National Electrical Codes
This equipment should be installed in compliance with local and national electrical codes.
Installation Codes
This device must be installed according to the latest version of the country national electrical codes. For North America,
equipment must be installed in accordance to the applicable requirements in the US National Electrical Code and the Canadian
Electrical Code.
Battery Replacement
Warning: Replace only with UL Recognized battery, certified for maximum abnormal charging current not less than 4mA. There
is a risk of explosion should the battery be replaced with a battery of an incorrect type. Dispose of used batteries according to the
instructions.
UL Listed and CSA Certified Power Supply Cord
For North American power connection, select a power supply cord that is UL Listed and CSA Certified, 3 - conductor, [16
AWG], terminated with a molded plug rated at 125 V, [13 A], with a minimum length of 1.5m [six feet] but no longer than 4.5m.
For European connection, select a power supply cord that is internationally harmonized and marked “<HAR>”, 3 - conductor,
minimum 1.0 mm2 wire, rated at 300 V, with a PVC insulated jacket. The cord must have a molded plug rated at 250 V, 10 A.
Installation codes
This device must be installed according to the latest version of the country national electrical codes. For North America,
equipment must be installed in accordance to the applicable requirements in the US National Electrical Code and the Canadian
Electrical Code.
Interconnection of Units
Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL certified type DP-1 or DP-2. (Note- when residing
in non LPS circuit)
Overcurrent Protection
A readily accessible Listed branch circuit overcurrent protective device rated 20 A must be incorporated in the building wiring.
Do Not Use the Switch as a Shelf or Work Space
Caution: Slide/rail mounted equipment is not to be used as a shelf or a work space. The rails are not intended for sliding
the unit away from the rack. It is for permanent installation at final resting place only, not used for service and maintenance