13. UL Listed and CSA Certified Power Supply Cord
14. Leakage >3.5mA
15. Add GND connection information
16. Installation codes
17. Interconnection of units
18.WEEE Directive
For North American power connection, select a power supply cord that is UL
Listed and CSA Certified, 3 - conductor, [18 AWG], terminated with a molded
plug rated at 125 V, [15 A], with a minimum length of 1.5m [six feet] but no
longer than 4.5m.
For European connection, select a power supply cord that is internationally
harmonized and marked "<HAR>", 3 - conductor, minimum 0,75 mm2 wire,
rated at 300 V, with a PVC insulated jacket. The cord must have a molded plug
rated at 250 V, 10 A."
WARNING: High leakage current; Earth connection essential before connect-
ing supply.
Before connecting this device to the power line, the protective earth terminal
screws of this device must be connected to the protective earth in the building
installation.
This device must be installed according to the latest version of the country
national electrical codes. For North America, equipment must be installed in
accordance to the applicable requirements in the US National Electrical Code
and the Canadian Electrical Code.
Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL
certified type DP-1 or DP-2. (Note- when residing in non LPS circuit)
Overcurrent Protection: A readily accessible Listed branch circuit overcurrent
protective device rated 20 A must be incorporated in the building wiring.
According to the WEEE Directive 2002/96/EC, all waste electrical and
electronic equipment (EEE) should be collected separately and not dis-
posed of with regular household waste.
Dispose of this product and all of its parts in a responsible and environ-
mentally friendly way.