Instructions Manual
10-5.Applicable Motors
● Applicable motors are 5-phase stepping motors ranging from 0.75A/phase ~ 1.4A/phase.
PK543-A(B)
Fig.1
PK544-A(B)
Fig.2
PK545-A(B)
Fig.3
PK564-A(B)
Fig.4
PK566-A(B)
Fig.5
PK564H-A(B)
Fig.6
PK566H-A(B)
Fig.7
PK569-A(B)
Fig.8
PK596-A(B)
Fig.9
PK599-A(B)
Fig.10
TS3667N1E2(N11E2)
Fig.11
TS3667N2E5(N12E5)
Fig.12
TS3667N3E7(N13E7)
Fig.13
103H5505-7040(7010)
Fig.14
103H5508-7040(7010)
Fig.15
103H5510-7040(7010)
Fig.16
103H6500-7041(7011)
Fig.17
103H6501-7041(7011)
Fig.18
103H7851-7051(7021)
Fig.19
103H7852-7051(7021)
Fig.20
103H7853-7051(7021)
Fig.21
( ) : Both axes
F
6
0.72
0.75
0.75
OFF
F
F
F
ON
0.72
103H8581-7041(7011)
Setting
DRIVE I.SEL
switch No.
OFF
F
OFF
OFF
Representative Motors
Current
(A/phase)
Torque
Data
Fig. No.
(5L)
(5L)
(5L)
Setting
MOTOR SEL
switch
ON
ON
ON
(10L)
(10L)
103H8582-7041(7011)
Basic
Angle
(°)
0.75
0.72
0.72
0.75
ORIENTAL MOTOR CO., LTD.
SANYO DENKI CO., LTD.
TAMAGAWA SEIKI CO., LTD.
F
Factory setting
1.4
0.75
0.72
0.72
0.72
0.75
0.72
1.4
(10L)
6
F
-
(10L)
(10L)
(5L)
Fig.22
Fig.23
OFF
-40-
Summary of Contents for GD-5410
Page 12: ...Instructions Manual 3 Name and Function of Each Section 3 1 Signal I O Connector J1 12 ...
Page 13: ...Instructions Manual 3 2 AC Input Motor Output Terminal Block J2 J3 13 ...
Page 33: ...Instructions Manual 10 3 I O Signal R3 1 Example Circuit Connection 33 ...
Page 39: ...Instructions Manual 10 4 Dimensions Unit mm 39 ...
Page 42: ...Instructions Manual 42 ...
Page 43: ...Instructions Manual 43 ...
Page 44: ...Instructions Manual 44 ...
Page 45: ...Instructions Manual 45 ...
Page 46: ...Instructions Manual 46 ...