Page 3: ...ical Specifications LANTIME Chassis 14 5 LANTIME M300 Front Connectors 16 6 LANTIME M300 Rear Connectors 18 6 1 AC DC Power Supply 18 6 2 COMx Timestring RS 232 21 6 3 Error Relay 22 6 4 Antenna Input GPS Reference Clock 23 6 5 Pulse Per Second Output 24 6 6 10 MHz Frequency Output 24 6 7 10 100BASE T Network Port IEEE 803 2 24 7 Installation GPS Antenna 25 8 Technical Appendix GPS Antenna Accesso...

Page 4: ...einberg Funkuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 01 03 2021 LANTIME Date 1st March 2021 1 ...

Page 5: ...you may only continue if you have understood and fulfilled all requirements In this documentation dangers and indications are classified and illustrated as follows DANGER The signal word indicates an imminently hazardous situation with a high risk level This notice draws attention to an operating procedure or similar proceedings of which a non observance may result in serious personal injury or de...

Page 6: ...isiko eines elektrischen Schlages Caution risk of electric shock IEC 60417 5041 Vorsicht heiße Oberfläche Caution hot surface IEC 60417 6056 Vorsicht Gefährlich sich bewegende Teile Caution moving fan blades IEC 60417 6172 Trennen Sie alle Netzstecker Disconnection all power plugs IEC 60417 5134 Elektrostatisch gefährdete Bauteile Electrostatic Sensitive Devices IEC 60417 6222 Information generell...

Page 7: ...y be used for the purpose described in this manual In particular the given limits of the device must be observed The safety of the installation in which the unit is integrated is the responsibility of the installer Non observance of these instructions can lead to a reduction in the safety of this device Please keep this manual in a safe place This manual is intended exclusively for electricians or...

Page 8: ...f soiling additional measures e g Installation in an air conditioned control cabinet required Transport Unpacking Installation If the unit is brought into the operating room from a cold environment condensation may occur wait until the unit is temperature controlled and absolutely dry before operating it When unpacking setting up and before operating the equipment be sure to read the information o...

Page 9: ... work properly and are undamaged Pay particular attention to the facts that the cables do not have kinks or that they are not too short around corners and no objects are placed on the cables Also make sure that all connections are secure Faulty shielding or cabling will endanger your health electrical shock and may destroy other equipment Ensure that all necessary safety precautions have been take...

Page 10: ...that the mains socket on the appliance or the mains socket of the house installation is freely accessible to the user so that the mains cable can be pulled out of the socket in case of emergency Outside the assembly group the device must be disconnectable from the power supply in accordance with the provisions of IEC 62368 1 e g by the primary line protection Installation and disassembly of the po...

Page 11: ...earth conductor via the protective earth connection terminal If an external earth connection is provided on the housing it must be connected to the equipotential bonding rail grounding rail The mounting parts without cable are not included in the scope of delivery Note Please use a grounding cable 1 5 mm2 Always pay attention to a correct crimp connection 8 Date 1st March 2021 LANTIME ...

Page 12: ... installed and when the doors are closed cooling fire protection shielding against electrical magnetic and electromagnetic fields Switch off in fault service case By switching off the devices are not disconnected from the power supply In the event of a fault or service case the devices must be immediately disconnected from all power supplies Follow the steps below Switch off the device Disconnect ...

Page 13: ...hese surfaces If necessary switch off the unit before installing or removing any equipment and allow it to cool down 2 7 Handling Batteries CAUTION The lithium battery on the receiver modules has a service life of at least 10 years If an exchange is necessary the following notes must be observed The device is equipped with a lithium battery The battery must not be short circuited or recharged Repl...

Page 14: ... destruction Prepare removal and installation of assemblies Unload yourself for example by touching a grounded object before touching assemblies Ensure that you wear a grounding strap on the wrist when working with such assemblies which you attach to an unpainted non conductive metal part of the system Use only tools and devices that are free from static electricity Transporting Assemblies Assembl...

Page 15: ...ive The product symbol on the left indicates that this electronic product must not be disposed of in domestic waste Return and Collection Systems For returning your old equipment please use the country specific return and collection systems available to you or contact Meinberg The withdrawal may be refused in the case of waste equipment which presents a risk to human health or safety due to contam...

Page 16: ...ite receiver GNS UC only GPS and Galileo an IRIG time code receiver or a long wave receiver DCF77 MSF WWVB as well as external NTP servers or a DCF77 GNSS combination as hybrid receiver can be used as reference time source A GNSS synchronized LANTIME consists of a GNSS satellite receiver a single board computer with integrated network card and a power supply A simplified LINUX operating system is ...

Page 17: ... material sheet steel Temperature range Operation 0 50 C 32 122 F Storage 20 70 C 4 158 F Relative humidity Operation max 85 non condensing at 30 C Maximum altitude Operation max 4000 m 13123 ft above sea level Acoustics 0 dB A IP protection class IP20 14 Date 1st March 2021 LANTIME ...

Page 18: ...inch 445 mm 17 51 inch 304 mm 11 98 inch 288 mm 11 32 inch External Ground Connection on the Housing This connector must be wired to an equipotential bonding bar earthing bar Connection is possible on both sides of the housing The mounting parts without cable are included in the scope of delivery LANTIME Date 1st March 2021 15 ...

Page 19: ... the display the op erating mode of the reference clock reference time is shown Instead of GPS NORMAL OPERATION the messages GPS COLD BOOT GPS WARM BOOT or GPS UPDATE ALMANAC can appear In case the antenna connection is interrupted the following message is shown GPS ANTENNA FAULTY GPS NORMAL OPERATION NTP Offset PPS 4µs UTC 12 00 00 Mon dd mm yyyy 2 By using the 4 arrows and the ESC F1 and F2 butt...

Page 20: ...connection it is possible to configure the parameters with a terminal program To establish a connection between the LANTIME and a PC use a NULL MODEM cable Configure your terminal pro gram with 38400 Baud 8 Databits no parity and one Stopbit 8N1 The terminal emulation has to be set to VT100 After connecting to the time server the lo gin message will be displayed Enter user name and password Defaul...

Page 21: ...x I 0 6A N Power 6 1 AC DC Power Supply Hotplug In a redundant power supply operation it is possible to remove or install one of the power supply units e g in case of defect from the system housing during operation Torque of screws A Please tighten the Torx screws A with the specified torque of max 0 6 Nm after installing the new power supply unit Required Tools Slot screwdriver 0 4mm thick 2 5mm ...

Page 22: ...The dissolved power supply can be removed with the handle C now 5 Put the new power supply in the free slot and secure it with the two previously dissolved Torx fastening screws A 6 Connect the 5 pin DFK jack of the power cable to the power supply and put the two slit screws B back on 7 The protective contact plug of the power cable can be reconnected to the power supply 8 The status LED of the ne...

Page 23: ...0 kJ h 170 61 BTU h N L AD10 PWR Power U 100V 240V N U 90V 265V max I 1 0A N f 50 60Hz N U 100V 200V N U 90V 250V max I 0 6A N 2 3 4 5 1 WARNING This equipment is operated at a hazardous voltage Danger to life due to electrical shock Only qualified personnel electricians may connect the device Never work with open terminals and plugs while the power is on All connectors must be protected against t...

Page 24: ...ransfer serial Baudrate framing 19200 8N1 default Timestring Meinberg Standard default Assignment Pin 2 RxD receive Pin 3 TxD transmit Pin 5 GND ground Connection type D SUB female 9pin Cable data cable shielded PC connector 1 1 COM x LANTIME Date 1st March 2021 21 ...

Page 25: ...DC 30 W AC 60 VA Switching current UL CSA 0 46 A 140 V AC 0 46 A 65 V DC 1 A 30 V DC Response Time ca 2 ms Normal Operation Mode Normal Operation CO NO connected CO NO NC Error Mode Error CO NC connected CO NO NC Error CO NO NC WARNING This equipment is operated at a hazardous voltage Danger to life due to electrical shock Never work with open terminals and plugs while the power is on When working...

Page 26: ...cable Output voltage 15 V 100 mA via antenna cable Connection type BNC female N standard female Cable type shielded coax Cable length max 300 m to RG58 max 700 m to RG213 Antenna GNSS IF 15 V BNC N Norm N type Antenna GNSS IF 15 V WARNING Working on the antenna system during thunderstorms Danger to life due to electrical shock Do not carry out any work on the antenna system or the antenna cable if...

Page 27: ... Frequency Output Output signal 10 MHz frequency Signal level TTL 2 5 V into 50 Ohm Connection type BNC female Cable shielded coax line 10 MHz Out 6 7 10 100BASE T Network Port IEEE 803 2 Signal 100BASE T Data transmission rate 10 100 Mbit s Connection type 8P8C RJ45 Cable Copper twisted pair e g CAT 5 0 Duplex Modes Half Full Autonegotiaton 100M 10M LAN x 24 Date 1st March 2021 LANTIME ...

Page 28: ...eded Selection of the Antenna location To receive enough satellites select a location that allows an unobstructed view of the sky otherwise there may be problems with the synchronization of the system There should be no obstacle in the line of sight between the antenna and the satellites In addition the antenna must not be installed under high voltage lines or other electrical light or electric ci...

Page 29: ...g caused by lightning strikes can be transmitted via the antenna cable and may cause damage to the receiver The receiver is pro tected against these effects by using the MBG S PRO surge protection Being installed in a waterproof housing the MBG S PRO is also suitable for outdoor installation Mein berg recommends the indoor installation as soon as possible after the antenna cable enters the buildin...

Page 30: ...able to the socket of the surge protection Earth cable to PE rail Cable circa 1 5 mm Ø attached to the surge protection as short as possible 4 The next step is to connect the supplied coaxial cable between the surge protector and receiver N Norm female N Norm male SMA female BNC female N Norm male N Norm female BNC male Receiver Antenna splitter SMA male M B G S P R O Optional LANTIME Date 1st Mar...

Page 31: ...mpensate the signal propagation time of the antenna cable therefore you need to enter the length of the antenna cable in meters or the compensation time in nanoseconds into the settings of your receiver Antenna Cable Length m The receiving satellite signal is delayed by the used coaxial cable Cable Delay Usage RG58U 5 ns m for GPS and GNS UC receivers H155 4 ns m for GNS and GNM receivers By enter...

Page 32: ...8 Technical Appendix GPS Antenna Accessories 8 Technical Appendix GPS Antenna Accessories Physical Dimensions LANTIME Date 1st March 2021 29 ...

Page 33: ...idth 9 MHz Frequencies Mixed frequency 10 MHz IF frequency 35 4 MHz Connector N Norm female connector Form factor ABS plastic case for outdoor installation Protection class IP66 Humidity 95 Temperature range 40 C to 85 C 40 to 185 F Weight 1 6 kg 3 53 lbs incl mounting kit 30 Date 1st March 2021 LANTIME ...

Page 34: ...ther values can be found in the data sheet of the cable used 8 2 Antenna Short Circuit Only for assembly groups with front display In case of an antenna line short circuit the following message appears in the display ANTENNA SHORT CIRCUIT DISCONNECT POWER If this message appears the clock has to be disconnected from the mains and the defect eliminated After that the clock can be powered up again T...

Page 35: ...uipped with two type N female connectors It has no dedicated input output polarity or prefered mounting orientation Phoenix CN UB 280DC BB Features High RF Performance Multiple Strike Capability 20 kA Surge Protection Bi directional Protection Mounting type Connection specific intermediate plugging Type Attachment plug Direction of action Line Shield Earth Ground Maximum continuous operating volta...

Page 36: ...tio SWR in a 50 Ω system typ 1 1 2 GHz Permissible HF power Pmax at VSWR xx 50 ohm system 700 W VSWR 1 1 200 W VSWR Capacity Core Earth typ 1 5 pF asymmetrical shield typ 1 5 pF Surge current resistance conductor ground C1 1 kV 500 A C2 10 kV 5 kA C3 100 A D1 2 5 kA Ambient temperature operation 40 C 80 C Altitude 2000 m above sea level Degree of protection IP55 Housing material Nickel plated bras...

Page 37: ...8 3 1 MBG S PRO Physical Dimensions 67 11 15 8 25 13 4 8 3 2 Installation and Grounding 34 Date 1st March 2021 LANTIME ...

Page 38: ...um polybrominated biphenyls PBBs and polybrominated diphenyl ethers PBDEs Bis 2 ethylhexyl phthalat DEHP Benzylbutylphthalat BBP Dibutylphthalat DBP Diisobutylphthalat DIBP above the legal threshold WEEE status of the product This product is handled as a B2B Business to Busi ness category product In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer Any trans...

Page 39: ... und Richtlinien übereinstimmt to which this declaration relates is in conformity with the following standards and provisions of the directives RED Richtlinie ETSI EN 303 413 V1 1 1 2017 06 RED Directive 2014 53 EU EMV Richtlinie ETSI EN 301 489 1 V2 2 3 2019 11 EMC Directive ETSI EN 301 489 19 V2 1 1 2019 04 DIN EN 61000 6 2 2019 2014 30 EU DIN EN 61000 6 3 2007 A1 2011 DIN EN 55032 2015 DIN EN 5...