12.6.12.2 Available BPE Modules
BPE Type
Connectors
Signals
Size
BPE-1040
4 x BNC female
Out 1 - Out 4: TC AM
4HP
BPE-1060
1
4 x BNC female
Out 1 - Out 4: DCF77 SIM
4HP
BPE-2000
4 x BNC female
Out 1: PPS, Out 2: 10 MHz
4HP
Out 3: TC DCLS, Out 4: TC AM
BPE-2001
4 x BNC female
Out 1: PPS, Out 2: 10 MHz
4HP
Out 3: TC DCLS, Out 4: TC DCLS
BPE-2010
4 x BNC female
Out 1 - Out 4: PPS
4HP
BPE-2014
4 x BNC female
Out 1 - Out 2: PPS
4HP
Out 3 - Out 4: 10 MHz
BPE-2016
2
4 x BNC Buchse
Out 1 - Out 4: progr. Pulses_1
4TE
10 V
PP
an 50
Ω
BPE-2020
4 x BNC female
Out 1 - Out 4: 10 MHz
4HP
BPE-2030
4 x BNC female
Out 1 - Out 4: TC DCLS
4HP
BPE-2050
4 x BNC female
Out 1 - Out 3: TC DCLS
4HP
Out 4: TC AM
BPE-2080
4 x BNC female
Out 1 - Out 4: 2048 kHz
4HP
BPE-2090
4 x BNC female
Out 1 - Out 4: progr. Pulses
4HP
BPE-2091
3
4 x BNC female
Out 1 - Out 4: progr. Pulses_1
4HP
(1)
When using the BPE-1060 module, important configuration parameters must be observed. In the web inter-
face, you must set the mode to DCF77 Marks in the "Clock
→
Programmable Pulse Outputs
→
Prog. Out 1"
menu. In the drop-down box "Signal" the setting Normal is to be selected. In the menu "Clock
→
Time Zone
→
Time Zone for external Outputs" the
Local Time Zone
must be selected.
If the corresponding time zone does not exist in this drop-down box, the time zone can be added manually
in the menu "System
→
Display
→
Edit Time Zone Table".
See
(2)
The outputs can be set by jumpers. Possible options are: PPS, Time Code DCLS, PPO_0, PPO_1, PPO_2
and PPO_3. Default jumper setting of this card is 4 x PPO_0 (Progr. Output 1 in the web interface).
(3)
All four outputs of this BPE module have to be configured via the upstream receiver. In the web inter-
face, the configuration of the output signals can be carried out via the menu "Clock
→
Programmable Pulse
→
Prog. Out 1". Here the option "PTTI 1PPS" must be selected to get a pulse length of 20
µ
s.