![Meinberg IMS LANTIME M500 Manual Download Page 104](http://html.mh-extra.com/html/meinberg/ims-lantime-m500/ims-lantime-m500_manual_1766291104.webp)
12.6.16.1 PIO - Configuration via the Web Interface
The PIO module is pre-configured by a jumper. The
default configuration of all ports is PPS (Pulse Per
Second). If this pre-configuration needs to be changed
to 10 MHz, the card must be removed and the jumper
position adjusted.
Via the web interface, each port can be set separately to "Input" or "Output". If a port is set to "Output",
the system PPS or the 10 MHz reference frequency is output signal at this port. If a port is set to "Input" the
incoming signal is compared to the system PPS or to the 10 MHz reference frequency. The offset values are
displayed in the status window.
98
Date: 19th March 2020
IMS - LANTIME M500
Summary of Contents for IMS LANTIME M500
Page 2: ......
Page 90: ...Figure Selection of programmable pulse outputs 84 Date 19th March 2020 IMS LANTIME M500 ...
Page 132: ......