![Meiko GK 60 Operating Instructions Manual Download Page 20](http://html1.mh-extra.com/html/meiko/gk-60/gk-60_operating-instructions-manual_1766021020.webp)
Operating instructions GK 60
Datei:BA_GK60_9670999_EN_1997-08.doc
9670999
20/24
W e reserv e the right to change ex ecution and construction!
MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
16.1 Tips for self-help in the case of faults
Fault:
Remedy
Pump does not run,
machine does not wash
The fuse failed.
The pump has a thermal overload which stops the
motor on excess temperature. The motor will restart
automatically after a preset cooling period.
Check the fuse and replace if necessary.
Filling or rinsing does not
stop automatically
Solenoid valve sticking on scale or other impurities.
Check that the valve is clean. If valve is worn or
excessively scaled, it should be replaced as a
complete unit.
The air trap opening (pressure vessel in the wash
tank) is blocked and must be cleaned.
Lifting and lowering
device does not function
The dirt trap of the solenoid valve is blocked and must
be cleaned.
The local water pressure is too low.
17
Maintenance
Regular maintenance is a prerequisite for the long-term reliable and safe operation of a
warewashing machine. Maintenance which is neglected or improperly carried out
increases the residual risk of unforeseen damage to property and persons, for which no
liability will then be assumed.
Maintenance work should only be conducted if the machine has been switched off
completely via the on-site power disconnection device.
Existing safety systems may not be removed!
CAUTION!
A functional test on all safety systems of the machine / installation is carried out during
every regular maintenance
We recommend that you take out a maintenance contract with our manufacturer’s agent
in order to ensure a long service life.
Fault:
Remedy
Machine does not fill.
No water available
Dirt trap blocked
Level switch defective
Solenoid valve defective
Cover safeguard defective