16.4 Parameter list
Par.
No.
Configuration
options
Use as
value
range
Unit
Factory
setting
Note
101
Wash program
Key 1
Parameters
1 ...50
-
3
Allocate the wash program to the
key I
Assignment adjustable
102
Wash program
Key 2
Parameters
1 ...50
-
11
Allocate the wash program to the
key II
Assignment adjustable
103
Wash program
Key 3
Parameters
1 ...50
-
13
Assign rinse programme -no. of
the key I+II pressed together;
Assignment adjustable
104
Rinse agent
Dosing quantity
Parameters
0.10 ...1.00
ml/Liter
water
0.2
Value can be read from the rinse
aid container label (dependant on
water quality)
105
Rinse program
Dosing quantity
Parameters
0.1...20.0
ml/Liter
water
2.0
Value can be read from the deter-
gent container label (dependant on
water quality)
107
Beep ON/OFF
Parameters
0/1
-
1
Switch on/off acoustic ready mes-
sage
111
Total Operation
time
Indication
Indication
5 figures
h
Operation time
query only
112
Total number of
wash cycles
Indication
5 figures
-
Wash cycles/loads,
query only
113
Total number of
wash cycles since
last reset
Indication
5 figures
-
Wash cycles/loads,
re-setting possible
114
Serial number
Indication
8 figures
-
Option for calling the serial number
119
IR-communication
Parameters
0/1
-
1
It is possible to shut off communi-
cation via IR interfaces. (0)
120
Total number of
wash cycles Indi-
cation
Parameters
0/1
-
0
Effective only upon power supply
reset ON/OFF
ATTENTION!
All changes to ser-
vice parameters will be
reversed.
Power supply reset must be car-
ried out within 5 minutes, otherwise
factory settings will not be loaded.
Without power supply reset, the
information 123 will be displayed.
201
Machine type
Parameters
101 ...104
-
101
101: EcoStar E/A1 (with FA, EW)
102: EcoStar E/A2 (minimal)
103: EcoStar E/A1 (with new dos-
ing technology / ADT)
104: EcoStar with TL or A0
Attention! Only assignment list and
machine sequences change
– no
parameters