16.3.2 Ventilating the rinse aid inlet
this display by pressing the “accept” key.
Now the dosage pump will be activated and the remaining running time will be indicated.
You can leave this leve
l by pressing the “0” key. The ventilation will be interrupted off.
16.3.3 Ventilating the detergent inlet
this display by pressing the “accept” key.
Now the dosage pump will be activated and the remaining running time will be indicated.
You can leave this
level by pressing the “0” key. The ventilation will be interrupted off.
Should the ventilation process be insufficient, repeat the process.
The function "vent detergent pipe" is not existing with machines including detergent
dosing system type
ADT
('Advanced Dosing Technology with depression dosing). The
detergent dosing pipe is vented automatically when the first cycle is running, after filling
of the detergent reserve container.
16.3.4 Configuration level
You can find the list of configuration parameters on this level (parameter numbers 2xx).
Here you can view these and modify them. You can also call up the status of the inputs
and outputs, or set the outputs for testing.
On the configuration level, you will first see the display below:
this corresponds to the viewing/modifying parameters. (see 16.3.5)
This corresponds to viewing the status of inputs. (see 16.3.6)