Settings / modifications / on-site adaptation
16.1 Using the keyboard for programming
Access codes for various user-levels have been defined. Once the complete code has
been entered, the entered code is compared with the internal code table. Depending on
the code entered, the corresponding user level will be accessed. 2 access codes are
available for each user level; the first is for restricted access, i.e. no modification of pa-
rameters is possible (viewing mode), and the second gives access to the entire range of
functions (viewing and modification).
In the short programming instructions accompanying every machine in the series, this is
described in condensed form.
For control programming, the power supply must be available but the machine must be
completely switched off (no LED must be illuminated).
Code entry:
View service data:
CODE 10000
Modify service data:
CODE 10001
View configuration data:
CODE 20000
The code numbers for the further levels can be found in the Service Manual.
16.2 Code entry
To get into the code entry mode, you should keep the k
ey “0” pressed (for around 3 sec-
onds) until you see
on the display unit..
By pressing the key “0” once again you can leave the programming area at any time.
The digit to be modified will flash.
Press the “I” key to increase the value/code indicated on the display unit, or press the “II”
key to decrease it, or press the “accept” key to save it. The next value will then flash and
will be the only one visible.
Function field
Accept /
modify
Increase value/
move forward
Decrease value/
move backwards
Exit / Start Pro-
gramming
Value field