5 PErFOrM TEsTiNG
Parameter
Default value Editable in
TM1700
Compression
Off
yes
No. of Control sec-
tions activated
1
yes (if applica-
ble)
Trig out mode
Off
yes
Duration
100ms
yes
Trig in source C, O,
CO, OC, OCO
Operate / Meas-
ure
yes
static resistance
Off
yes
Dynamic resistance
Off
yes
Coil resistance
Off
yes
Transducer type
Analog/Digital
Analog
yes
Transducer type Lin-
ear/Angular
same as original
breaker
No
Absolute / relative
Absolute
yes
Nominal stroke
same as original
breaker
yes (Per Motion
channel. Before
only one entry
per breaker)
Conversion - Conver-
sion table
No conversion
yes (if applica-
ble, i.e. if there
is a calculated
MOTiON graph
defined in the
test plan for the
corresponding
Objectid)
Conversion Linear -
Conversion factor
1
yes (if applica-
ble, i.e. if there
is no calculated
MOTiON graph
defined in the
test plan for the
corresponding
Objectid)
speed calculation
points
same as original
breaker
yes
Import circuit breaker set-ups from
CABA Win
you can import pre-defined breakers from CABA Win
into CABA Local in the instrument.
IMPORTANT
The import function only supports circuit
breaker set-up/test plans created or ap-
proved by Megger Sweden AB. Megger
Sweden AB takes no responsibility for
circuit breaker set-up/test plans manually
edited or created by users.
1]
Select “Import Breaker” from the Breaker
List.
2]
Browse for the breaker you wish to import
and click the “IMPORT” button.
Summary of Contents for TM1700 Series
Page 2: ......
Page 15: ...BL1448GE ZP BL16E TM1700 series 15 3 System overview...
Page 25: ...BL1448GE ZP BL16E TM1700 series 25 4 CABA Local...
Page 61: ...BL1448GE ZP BL16E TM1700 series 61 5 Perform testing...
Page 75: ...BL1448GE ZP BL16E TM1700 series 75 7 Specifications...
Page 85: ...BL1448GE ZP BL16E TM1700 series 85 10 Quick Guide...
Page 91: ......