5 MENU OPTIONS
expressed (amperes, percentage of nominal current
or as a ratio). In addition, you can specify the nominal
current itself.
The available settings are listed below.
A-meter 1
Menu
Settings
Description
Range
Auto
Range is selected automatically
To get the best result possible
when using short measuring
time, you should not use the
Auto mode.
Low
Low range is selected
1)
High
High range is selected
1)
Unit
Ampere
Current reading in Ampere
% of In
Current reading as percentage
of nominal current
I1/I2
Current reading as the ratio of
generated current (I1) to current
measured by “AMMETER 2” (I2)
Nominal
Current
Value in A
Here you can set the value of
the nominal current
1) The value for range Low or High depends on the output
configuration, see "Specifications"
V/A METER
In this menu option you can select to use the voltme-
ter or the second ammeter ("A-METER 2"). You can
also modify the settings for the instruments. You can
select the range and the unit in which the reading is
to be expressed (volts/amperes or percentage of nomi-
nal voltage/current). In addition, you can specify the
nominal current/voltage itself and have the turns ratio
for a current transformer displayed.
First in the menu you have to select between "A-
METER 2" or "VOLTMETER". Select the desired
instrument by pressing
. The instrument will be
activated and you can now modify its settings.
The available settings are listed in the table below.
V/A Meter
Menu
Settings
Description
A-Meter 2,
Range
Auto
Range is selected automati-
cally.
To get the best result possible
when using short measuring
time, you should not use the
Auto mode.
0 – 2 A
0 – 2 A range is selected.
0 – 20 A
0 – 20 A range is selected.
A-Meter 2,
Unit
Ampere
Current reading in Ampere.
% of In
Current reading as percentage
of nominal current
CT ratio
Ratio for a current transformer
is presented as primary current
/ secondary current (Nom I)
A-Meter 2,
Nom I
Value in A
Here you can set the value of
the nominal current
V-Meter,
Range
Auto
Range is selected automati-
cally
0 – 0.2 V
0 – 0.2 V range is selected
0 – 2 V
0 – 2 V range is selected
0 – 20 V
0 – 20 V range is selected
0 – 200 V
0 – 200 V range is selected
V-Meter,
Unit
Volt
Voltage reading in Volts
% of Vn
Voltage reading as percentage
of nominal voltage (Vn)
V-Meter,
Nom V
Value in V
Nominal voltage (Vn). Enter
the nom V value on which
percentage will be based.
SYSTEM
In this menu option you can:
▪
Select the unit in which the timer results will be expressed.
▪
Activate DC-measurement function.
▪
Specify the delay time for the automatic shutoff (AUTO
OFF) function.
▪
Activate the Auto-Dump function and select the language
that will be used on the display.
▪
Set the INT level and the threshold for detection that the
generated current is interrupted.
The available settings are listed in the table below.
System
Menu
Settings
Description
Timer
Seconds
Time displayed in seconds.
Cycles
Time displayed in number of mains
voltage cycles.
hh:mm
Time displayed in hours, minutes
and seconds. Seconds are displayed
up to 1 min.
DC- Meas-
urement
On/Off
INGVAR can be set to measure
DC-current (A-meter 1 and 2) and
DC-voltage (V-meter). See note.
OFF Delay
Cycles
Specify the number of mains voltage
cycles which the automatic shut-off
is to be delayed (in accordance with
the preset stop condition).
Auto-Dump On/Off
INGVAR can be set to automatically
dump test data to a PC when the
generation is stopped. See Appen-
dix 1.
Summary of Contents for INGVAR
Page 2: ......
Page 9: ...BH0654BE ZP BH05E 9 1 Safety...
Page 17: ...BH0654BE ZP BH05E 17 2 Introduction...
Page 19: ...BH0654BE ZP BH05E 19 4 Display...
Page 33: ...BH0654BE ZP BH05E 33 5 Menu options...
Page 47: ...BH0654BE ZP BH05E 47 5 Menu options...
Page 67: ...BH0654BE ZP BH05E 67 Appendix 1...
Page 70: ...70 ZP BH05E BH0654BE Index...
Page 71: ......