11
LENGTHS OF PIPE needed for each PIPE FITTING. Write these lengths on
your piping schematic at each fitting.
6.
TOTAL all the EQUIVELENT LENGTHS OF PIPE needed for each PIPE FITTING
and add to your total of straight length of pipe. This will give you a new and more
accurate total pipe length needed.
7.
Take your new total of EQUIVELENT LENGTH OF PIPE IN FEET back to TABLE
1 and use this number to determine the PIPE SIZE you need.
Specific Cabinet Cooler Pipe Size
To obtain maximum performance from the Cabinet Cooler, accurate measures of air
pressure and air volume must be obtained. Line pressure of 70-80 psi (5-5.5 Bar) can
be present without a sufficient volume (cfm) of air.
To ensure that both pressure and volume are present to efficiently operate the Cabinet
Cooler a line size of 3/8” pipe or ½” hose should be used for applications 10ft from the
main header. Use ½” pipe or ¾” hose up to 20ft. For pipe size over 20ft from he header
please refer to section 5.