EN
21
3. Check that the insulation on the electrode
and non-return cables is free from nicks,
cracks and other damage that can cause
leakage current.
4. Keep the return cable and its connections
in good condition – clean the surface of the
work bench where the return cable clips are
connected at regular intervals.
CONNECTION OF MAINS VOLTAGE
• Check that the mains voltage corresponds
to the rated voltage on the type plate.
• Allow an authorised electrician to install an
earthed power point if the plug does not fit
in the power point.
• Switch off the product with the power
switch and pull out the plug before working
on the product.
• Do not attempt to repair the product
yourself. Take it to an authorised electrician
or service centre.
• Wait 5 minutes after switching off and
unplugging the product so that the
capacitors have time to discharge before
carrying out service or any other work on
the product. Never touch live parts.
• The product is supplied with 1-phase 230 V
50/60 Hz.
USE
CONFIGURATION FOR MMA
1. Switch on the power source and set the
MMA/MIG/TIG selector in MMA mode.
2. Set the correct welding current for the
welding electrode to be used, as per the
table below.
Electrode diameter (mm) Setting
1.0
1
2
3
OVERLOAD PROTECTION
The product’s output spools and rectifier are
provided with overheating protection that
prevents exceeding the output data and
maximum intermittence factor.
ELECTRICAL INSTALLATION
WARNING!
Highly dangerous – risk of electric shock
EARTHING AND RADIO
INTERFERENCE PROTECTION
The product must be connected to earth.
The product generates, uses and can emit
radio-frequency energy, and if not installed
and used according to the instructions can
cause interference to radio, television and other
electronic equipment. Correct earthing can limit
or eliminate such problems.
Disruptive, radio-frequency energy can be
emitted in several different ways.
• Direct radiation from source of welding
current.
• Direct radiation from welding cables.
• Direct radiation as a result of mains
interaction.
• Indirect radiation from non-earthed metal
objects.
Follow the instructions below to counteract such
interference.
1. Keep the leads between the mains outlet
and product as short as possible and if
possible provide the leads with metal
shielding connected to earth.
2. Keep the welding cables (electrode cable
and return cable) as short as possible.
Fasten if possible the welding cables
together to form a pair with insulating tape
or the equivalent.
Summary of Contents for 016793