background image

Fig. 2

Fig. 3

Fig..1  

ASSEMBLY DIMENSIONS

Important: 

all dimensions are referenced from the center of the hinge.

*Measurements in millimeters.

5 of 11  

MAXIMUM 

DIMENSIONS

Max 2 m

Max 4 m

  

Max 6 m

  

  

LIGHT
400KG

HLR 240

110°

HLR 240

 - 95°

HLR 360

 -115°

HLR 360

95°

  

MEDIUM
600KG

HLR 240

110°

HLR 240

 - 95°

HLR 360

 -115°

HLR 360

90°

HEAVY
800KG

HLR 240

110°

HLR 360

115°

 

HLR

 

OPENING INWARDS (Fig. 2)

M

A

B

C

85°

195

185

90

90°

180

180

90

95°

165

180

90

100°

150

180

90

105°

140

180

90

110°

125

180

90

115°

115

180

90

120º

105

180

90

OPENING OUTWARDS (Fig. 3)

M

A

B

C

85°

200

180

100

90°

180

180

100

95°

165

180

100

100°

150

180

100

105°

125

180

100

HLR 

OPENING INWARDS (Fig. 2)

M

A

B

C

85°

130

125

70

90°

120

120

70

95°

110

120

70

100°

100

120

70

105°

93

120

70

110°

85

120

70

115º

85

115

70

OPENING OUTWARDS (Fig. 3)

M

A

B

C

85°

130

120

80

90°

120

120

80

95°

110

120

80

100°

100

120

80

Summary of Contents for HLR240 BAC-1.3

Page 1: ...INSTRUCTION MANUAL AUTOMATIC GATE MECHANISM HLR240 BAC 1 3 HLR360 BAC 1 3 Ed2 27 08 18...

Page 2: ...r of which it will be a component has been identified and declared to comply with the terms of Directive 2006 42 EEC and subsequent amendments We put the CE conformity marking on the machine Plate num...

Page 3: ...s install a differential with a value of 0 03 A and a thermomagnetic switch with an opening of the contacts of at least 3 mm provided with overload and short circuit protection Connect the yellow gree...

Page 4: ...50 bar Rod stroke length 242 mm 362 mm Closing manoeuvre time 20 s 31 s Opening manoeuvre time 17 s 26 s Closing force 637 Kg Opening force 508 Kg Maximum gate length 4 m 6 m Temperature range 15 to 8...

Page 5: ...ning and closing Ti time between complete manoeuvres opening closing Graph 1 Note To ensure the full closing and opening of the gate it is necessary to increase the manoeuvring times by 5 sec onds The...

Page 6: ...800KG HLR 240 110 HLR 360 115 HLR OPENING INWARDS Fig 2 M A B C 85 195 185 90 90 180 180 90 95 165 180 90 100 150 180 90 105 140 180 90 110 125 180 90 115 115 180 90 120 105 180 90 OPENING OUTWARDS Fi...

Page 7: ...vertical line as possible Dimension C remain constant in both motors model 360 C 90 mm and model 240 C 70 mm Example What would be the dimension A and what engine should I use to automate a gate with...

Page 8: ...ASSEMBLY INSTRUCTIONS 7 of 11 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15...

Page 9: ...tion move the ring at the end of the stroke on the rod Fig 9 page 7 to the telescopic bushing Fig 10 page 7 and attach it with the allen screw Now we can activate the motor electrically Reposition the...

Page 10: ...e RED BLUE View of the motor from below LOCKING OPERATION The BAC system incorporated in the HLR device offers a wide variety of possibilities Here is how it should be manipulated to get the most out...

Page 11: ...h and it is not an obstacle that must be released In order to be able to do without a limit switch when opening it is necessary for the panel to have the option that when the gate is opening and finds...

Page 12: ...Kit and Gate supp 240 A232 11001 K1 Pillar supp Kit and Gate supp 360 A232 11002 K1 21 Hydraulic lock A232 21002 00 22 Hydraulic hose in metres 80736 23 Hose assembly kit A232 22003 K1 No NAME Ref 1...