10. Specifications 

10.1. Technical specifications 

10.1.1 The ColumbaTD bracelet

 

GSM/GPRS    

 

 

 

 

850*/900/1800/1900 MHz 

GPS    

 

 

 

 

 

-150dB (maximum sensibility) 

RF (receive only) 

 

 

 

 

2.402 GHz 

 
10.1.2 The Charger 
RF (transmit only) 

 

 

 

 

2.402 GHz, maximum power 10dB 

Power supply (North America):  

                      120V 60 Hz 350mA 

Power supply (Europe): 

 

 

           220V 50 Hz 350mA 

*for the quadriband model  only. 

 

10.2. Network services 

 
The ColumbaTD is certified to use GSM/GPRS networks, using bands 850*/900/1 800/1 900 MHz  It can be use only on those 
bands, ColumbaTD services depend on the network coverage in the frequencies mentioned before. It is important to verify the 
network coverage in your region before activating the ColumbaTD. 
 
The ColumbaTD, as all mobile telephone, uses radio signals, mobile or fixe network that cannot always guarantee connection under 
all conditions. In consequence, do not only rely on the ColumbaTD for your essential emergency and assistance communication. 
 
Medical Mobile does not assume any responsibility for failure of GSM/GPRS services system. 
 

10.3. GSM Positioning Service  
 

The ColumbaMC is certified to use GSM positioning system. GSM positioning system is a technology offered by your mobile service 
provider. Some providers do not offer the GSM positioning.  Then it is possible that GSM positioning services are not available on the 
ColumbaTD.

Summary of Contents for ColumbaTD

Page 1: ......

Page 2: ...earer 5 4 Automated alerts 5 4 1 Low battery 5 4 2 Leaving protected zone 6 Conditions and usage environment 6 1 General instruction 6 2 Wet environment 6 3 Particular conditions 6 3 1 Pacemaker 6 3 2...

Page 3: ...d prior usage The reading of this guide must be completed with the reading of the General Condition and Subscription Formulary of the ColumbaTD service include in the box containing the ColumbaTD syst...

Page 4: ...e low level of the battery and that a recharge is necessary The red light constantly remains lit when the alert button is activated or if the ColumbaTD tries to establish a distant contact with inform...

Page 5: ...Indicates that the charger is functional E Plug for the electrical supply wire F Base for the unbolting key G Radio antenna RF Battery block A Lock Drive in the mechanism to maintain the battery bloc...

Page 6: ...on the documents On the days following the reception of the formulary a representative will contact the subscriber to complete the activation of the ColumbaTD system BEFORE THE REPRESENTATIVE CALLS T...

Page 7: ...d bracelet wrap each around the wearer s wrist Choose the bracelet which rod extremity of the bracelet that goes in the lock is near the holes on the other extremity of the bracelet Once the appropria...

Page 8: ...he wire of the transformer in the plug located behind the charger Plug the transformer in a wall plug A blue light will turn on when the charger will be ready to function The charger has a 2 4 GHz tra...

Page 9: ...the red light will turn on to indicate that the charge is in process the red light will turn off once the charge is completed The process lasts approximately two hours To remove the Battery block of...

Page 10: ...l turn on on the battery block indicating that the charge is in process The yellow light will turn off once the charge is completed When the load of the ColumbaTD is really low or the initial charge i...

Page 11: ...block if fixed to the charger may supply the charger for several hours even in the case of power failure If the charger is moved ex during a trip by leaving the battery block on its base the charger...

Page 12: ...this mode is operational only in zones where GSM GPRS and GPS network are available 4 4 Emergency Mode To activate the alert button it must be pushed for a minimum of two seconds in order to avoid a...

Page 13: ...mbaTD by contacting the medical assistance central where they will be asked their secret code It might also be possible to obtain localization by acceding to the www medicalmobile com website and foll...

Page 14: ...power and the microphone is extremely sensitive it not required or intended to be held directly in front of the face 5 3 2 Contact the ColumbaTD wearer In case of an emergency or assistance situation...

Page 15: ...lar Conditions 6 3 1 Pacemaker In accordance with the independent researches and recommendations of Wireless Technology Research we recommend to persons having a pacemaker to i Always keep the Columba...

Page 16: ...ColumbaTD in hospitals or in care centres when the post up regulations in certain zone stipulates it 6 3 4 Security onboard a plane The utilization of your bracelet is forbidden during flight time Yo...

Page 17: ...spiteful use of the information transmitted via internet 8 After Sale Service After sale service is only available in metropolitan France In case of difficulty with the device do not go back where it...

Page 18: ...ies mentioned before It is important to verify the network coverage in your region before activating the ColumbaTD The ColumbaTD as all mobile telephone uses radio signals mobile or fixe network that...

Page 19: ...he ColumbaTD is always inside the RF zone the battery autonomy is up to one month However it is advice to preventively charge once a week the device 10 5 2 Regular Mode Autonomy When the ColumbaTD goe...

Page 20: ...l Standardization and while emitting the highest SAR value of the device on all the frequency bands tested Although SAR evaluation is carried out to the highest SAR value reported to the authorities t...

Page 21: ...PCS Cellular GSM GPRS Wrist Worn Personal Location device FCC ID TV9 MICLM C001 complies with SAR Specific Absorption Rate RF exposure requirements specified in FCC 47 CFR 2 1093 and Health Canada s S...

Page 22: ...very software of the ColumbaTD system is protected by pending patents or copyrights Any copy modification opposite engineering is strictly forbidden and could lead to legal prosecution 1 1 2 Trademark...

Page 23: ...o operate the equipment 11 Legal Advice 11 3 Conformity Declaration CE Marking We Medical Mobile SAS located at 102 Ave des Champs lys es 75008 Paris France declare under our responsibility that our p...

Page 24: ...elivery time He will also be responsible for the lack of conformity resulting from the packaging mounting instructions or installation when the contract stipulates that the seller is in charge of the...

Page 25: ...e the duration of the warranty Notwithstanding what precedes the batteries as for them are only warranted 6 months Only the product initial buyer to an authorized dealer the consumer benefits from the...

Page 26: ...der 60 of the expected initial capacity or if they let escape their contents In case of immobilization of the product for more than seven days the duration of the initial warranty will be expended acc...

Page 27: ...tion reparation or product maintenance unauthorized by Medical Mobile Utilization installation connection not conform to Medical Mobile specifications Utilization of unsuitable accessories Damage to t...

Page 28: ...ection without notice At the time of printing this document the enclosed information is considered by Medical Mobile to be veracious and exact ColumbaTD and Medical Mobile are the property of Medical...

Reviews: