![Mecal CDA10 Use And Maintenance Manual Download Page 94](http://html1.mh-extra.com/html/mecal/cda10/cda10_use-and-maintenance-manual_1758745094.webp)
CRIMP DATA ANALYZER
CDA10
REV.01
92
6.8
FAULTS
PROBLEM
CAUSE
SOLUTION
The machine and the
equipment does not start.
Power supply not connected to the
mains.
Connect the power supply
to the mains.
Switch set to OFF position (O).
Move the switch to the ON
position (I).
The equipment does not
start (press running).
Electrical cables disconnected and/or
incorrectly connected to the load cell.
Check the electrical
connections between the
load cell and the
equipment.
Check the signal
connections between the
load cell and the
equipment.
The equipment does not
stop the machine in case of
Fail.
Cables disconnected and/or
incorrectly connected to the load cell.
Check the electrical
connections between the
load cell and the
equipment.
Check the signal
connections between the
load cell and the
equipment.
Load cell not configured.
Configure the load cell as
indicated in the
corresponding paragraph.
If a message appears on the controller display together with the problem, see paragraph 6.6.6
ERROR MESSAGES.
Summary of Contents for CDA10
Page 2: ......
Page 3: ......
Page 11: ...CRIMP DATA ANALYZER CDA10 REV 01 9...
Page 20: ...CRIMP DATA ANALYZER CDA10 REV 01 18...
Page 22: ...CRIMP DATA ANALYZER CDA10 REV 01 20...
Page 31: ...CRIMP DATA ANALYZER CDA10 REV 01 29...
Page 33: ...CRIMP DATA ANALYZER CDA10 REV 01 31...
Page 36: ...CRIMP DATA ANALYZER CDA10 REV 01 34...
Page 41: ...CRIMP DATA ANALYZER CDA10 REV 01 39...
Page 43: ...CRIMP DATA ANALYZER CDA10 REV 01 41...
Page 48: ...CRIMP DATA ANALYZER CDA10 REV 01 46...
Page 50: ...CRIMP DATA ANALYZER CDA10 REV 01 48...
Page 65: ...CRIMP DATA ANALYZER CDA10 REV 01 63...
Page 66: ...CRIMP DATA ANALYZER CDA10 REV 01 64...
Page 67: ...CRIMP DATA ANALYZER CDA10 REV 01 65...
Page 69: ...CRIMP DATA ANALYZER CDA10 REV 01 67...
Page 95: ...CRIMP DATA ANALYZER CDA10 REV 01 93...
Page 99: ...CRIMP DATA ANALYZER CDA10 REV 01 97...
Page 101: ...CRIMP DATA ANALYZER CDA10 REV 01 99...
Page 113: ...CRIMP DATA ANALYZER CDA10 REV 01 111 MAINTENANCE LOG DATE OPERATOR DESCRIPTION OF INTERVENTION...
Page 115: ...CRIMP DATA ANALYZER CDA10 REV 01 113...
Page 117: ...CRIMP DATA ANALYZER CDA10 REV 01 115...
Page 119: ...CRIMP DATA ANALYZER CDA10 REV 01 117 9 1 MACHINE LAYOUT...