5.2.1.2
STANDARD
The operations to be carried out to connect the load cell electrically are:
•
Check that the switch, located on the press or in the electrical cabinet/panel, is in the OFF (O)
position.
•
Disconnect the press from the electrical mains.
•
Open the electrical box of the press.
•
Intercept the cables from the load cell and BCC: white, brown, yellow, green, rose and grey.
•
Connect the brown cable to the pos.4 input [+18V] on the terminal board (combined with the
cable present).
•
Connect the white cable to the pos.5 input on the terminal board (combined with the cable
present).
•
Connect the grey cable to the pos.10 input on the terminal board (combined with the cable
present).
•
Connect the green cable to the pos.12 input on the terminal board (combined with the cable
present).
•
Connect the yellow cable to the black cable with PD indication by means of the supplied clamp.
•
Connect the rose cable to the black cable with PX indication by means of the supplied clamp.
•
Close the electrical box with the screws.
•
Connect the press to the electrical mains.
•
Move the switch to the ON (I) position.
•
Configure the load cell [see the relative paragraph].
Summary of Contents for CDA10
Page 2: ......
Page 3: ......
Page 11: ...CRIMP DATA ANALYZER CDA10 REV 01 9...
Page 20: ...CRIMP DATA ANALYZER CDA10 REV 01 18...
Page 22: ...CRIMP DATA ANALYZER CDA10 REV 01 20...
Page 31: ...CRIMP DATA ANALYZER CDA10 REV 01 29...
Page 33: ...CRIMP DATA ANALYZER CDA10 REV 01 31...
Page 36: ...CRIMP DATA ANALYZER CDA10 REV 01 34...
Page 41: ...CRIMP DATA ANALYZER CDA10 REV 01 39...
Page 43: ...CRIMP DATA ANALYZER CDA10 REV 01 41...
Page 48: ...CRIMP DATA ANALYZER CDA10 REV 01 46...
Page 50: ...CRIMP DATA ANALYZER CDA10 REV 01 48...
Page 65: ...CRIMP DATA ANALYZER CDA10 REV 01 63...
Page 66: ...CRIMP DATA ANALYZER CDA10 REV 01 64...
Page 67: ...CRIMP DATA ANALYZER CDA10 REV 01 65...
Page 69: ...CRIMP DATA ANALYZER CDA10 REV 01 67...
Page 95: ...CRIMP DATA ANALYZER CDA10 REV 01 93...
Page 99: ...CRIMP DATA ANALYZER CDA10 REV 01 97...
Page 101: ...CRIMP DATA ANALYZER CDA10 REV 01 99...
Page 113: ...CRIMP DATA ANALYZER CDA10 REV 01 111 MAINTENANCE LOG DATE OPERATOR DESCRIPTION OF INTERVENTION...
Page 115: ...CRIMP DATA ANALYZER CDA10 REV 01 113...
Page 117: ...CRIMP DATA ANALYZER CDA10 REV 01 115...
Page 119: ...CRIMP DATA ANALYZER CDA10 REV 01 117 9 1 MACHINE LAYOUT...