![Mecal CDA10 Use And Maintenance Manual Download Page 91](http://html1.mh-extra.com/html/mecal/cda10/cda10_use-and-maintenance-manual_1758745091.webp)
CRIMP DATA ANALYZER
CDA10
REV.01
89
To test sensitivity, it is advisable to start creating large crimping errors, moving toward the creation
of smaller and smaller faults, or temporarily disabling the Drift compensation function.
The value is set to YES (function enabled) or NO (function disabled). The default value is set to YES.
•
AVG Samples
This function lets the operator apply an average filter to the force curves.
It can in some
circumstances help to counteract the effects of high-frequency noise.
The Filter works by setting each sample point on the curve so that it is the average value of the
adjacent group of original sample points. This suppresses the high-frequency components of the
signal. As the number of averaged samples increases, the signal becomes more uniform.
The value can be an odd number between 1 and 51. The default value is set to 1 (no average).
•
TrigForce
The TrigForce option lets you ignore crimping cycles with a peak force below a set threshold. The
intention is to prevent unwanted controller failures when crimping empty terminals in busbar
applications.
The value sets a threshold, in percentage, of the reference curve peak.
During production, a crimping curve with a peak force below this threshold should not cause a "Fail"
result.
The minimum (and default) value is 0%, which actually disables this function, while the maximum
value is 70%.
Summary of Contents for CDA10
Page 2: ......
Page 3: ......
Page 11: ...CRIMP DATA ANALYZER CDA10 REV 01 9...
Page 20: ...CRIMP DATA ANALYZER CDA10 REV 01 18...
Page 22: ...CRIMP DATA ANALYZER CDA10 REV 01 20...
Page 31: ...CRIMP DATA ANALYZER CDA10 REV 01 29...
Page 33: ...CRIMP DATA ANALYZER CDA10 REV 01 31...
Page 36: ...CRIMP DATA ANALYZER CDA10 REV 01 34...
Page 41: ...CRIMP DATA ANALYZER CDA10 REV 01 39...
Page 43: ...CRIMP DATA ANALYZER CDA10 REV 01 41...
Page 48: ...CRIMP DATA ANALYZER CDA10 REV 01 46...
Page 50: ...CRIMP DATA ANALYZER CDA10 REV 01 48...
Page 65: ...CRIMP DATA ANALYZER CDA10 REV 01 63...
Page 66: ...CRIMP DATA ANALYZER CDA10 REV 01 64...
Page 67: ...CRIMP DATA ANALYZER CDA10 REV 01 65...
Page 69: ...CRIMP DATA ANALYZER CDA10 REV 01 67...
Page 95: ...CRIMP DATA ANALYZER CDA10 REV 01 93...
Page 99: ...CRIMP DATA ANALYZER CDA10 REV 01 97...
Page 101: ...CRIMP DATA ANALYZER CDA10 REV 01 99...
Page 113: ...CRIMP DATA ANALYZER CDA10 REV 01 111 MAINTENANCE LOG DATE OPERATOR DESCRIPTION OF INTERVENTION...
Page 115: ...CRIMP DATA ANALYZER CDA10 REV 01 113...
Page 117: ...CRIMP DATA ANALYZER CDA10 REV 01 115...
Page 119: ...CRIMP DATA ANALYZER CDA10 REV 01 117 9 1 MACHINE LAYOUT...